Channelized Line Card Run/Fail LED States
The Run/Fail LED on the Channelized line card indicates the overall status of the card. These LEDs are
illuminated steady green during normal operation.
If the LED is not green, use the troubleshooting information in the table to diagnose the problem.
Table 73: Channelized Line Card Run/Fail LED States
Troubleshooting
Description
Color
None needed.
Card powered with no
errors detected
Green
Errors were detected during the POSTs. It is likely that the errors
were logged to the system's command line interface during the
boot process.
Card powered with
error(s) detected
Red
Verify that the POWER LEDs on the PFUs are green. If they are
not, refer to
Checking the LED on the PFU, on page 137
for
troubleshooting information.
Card is not receiving
power
None
Verify that the power source is supplying ample voltage and
current to the chassis.
Verify that the card is properly installed per the instructions in
this document.
If all of the above suggestions have been verified, it is possible
that the line card is not functional. Please contact your service
representative.
Channelized Line Card Active LED States
The Active LED on the channelized line card indicates that the operating software is loaded on the card and
that the card is ready for operation.
Installed line cards remain in ready mode until their corresponding packet processing card is activated during
configuration. While in ready mode the Active LED is off. After the packet processing card is activated, the
line card installed in the upper-rear chassis slot behind the packet processing card is also activated. The line
card installed in the lower-rear chassis slot behind the packet processing card enters standby mode.
If the LED is not green, use the troubleshooting information in the table to diagnose the problem.
ASR 5000 Installation Guide
161
Applying Power and Verifying the Installation
Card-Level LEDs on the Channelized (STM-1/OC-3) Line Card
Summary of Contents for ASR 5000
Page 16: ...ASR 5000 Installation Guide xvi About this Guide Contacting Customer Support ...
Page 64: ...ASR 5000 Installation Guide 48 Installation Procedure Overview Laser Notice ...
Page 100: ...ASR 5000 Installation Guide 84 Line Card Installation Installing the XGLC ...
Page 122: ...ASR 5000 Installation Guide 106 Cabling the Fast Ethernet 10 100 Line Card FLC2 Interfaces ...
Page 206: ...ASR 5000 Installation Guide 190 Removing and Installing SMC PC Cards Removing PC Cards ...
Page 212: ...ASR 5000 Installation Guide 196 Replacing the Chassis Air Filter Installing the Air Filter ...
Page 220: ...ASR 5000 Installation Guide 204 Replacing a Power Filter Unit What to do with the Failed PFU ...
Page 266: ...ASR 5000 Installation Guide 250 Safety Electrical and EMC Certifications Korean EMC ...
Page 270: ...ASR 5000 Installation Guide 254 Environmental Specifications Chassis Air Flow ...