76
-
13.3.2 Group parameters
Proceed from the MENU mode.
By tapping the
▼
button of the item for setting, the screen moves to the input screen.
By selecting the display settings on the setting menu screen and then selecting the group parameters, the
following screen is displayed.
The group being specified by the number in the upper left "Group" can be set.
Setting the group name
Set the group name. This group name is used in the screen display and used as the file name of
the recorded data.
Channel
Set the channel to be registered in the group. The registration is cancelled by setting blank.
Trend display
Every time the ENTER key is pressed after selecting “Y” and ”N” are switched alternatively. The
trend with N is not displayed even if the channel has been registered. The data of channel with N
selected are not recorded in the file.
Size
It is the thickness of the trend line. It can be selected from 1 to 5.
Setting the trip line
Set the trip line (dotted line) to be displayed on the trends.
Position
Set the display position of the trip line in the range 0-99% of the display width.
Color
Select the color of the trip line.
Size
Select the thickness of the trip line from 1 to 5.