![Chicago Dryer King Edge Instruction Manual Download Page 197](http://html1.mh-extra.com/html/chicago-dryer/king-edge/king-edge_instruction-manual_2598167197.webp)
King Edge
3024-016c
C-15
Start Testing
To test any of the CHI Panel’s functions,
follow these first steps:
Locate the appropriate schematic(s).
Turn power OFF at the main disconnect
switch.
Open the right endframe door and locate
the spread/feed controller boards. During
the test, the LED’s will light to show the
control signals.
WARNING
This safety interlock switch
is only to be defeated
temporarily while performing
this procedure. Never
operate the unit unless
all safety systems
are working correctly.
Serious Injury Could Result.
The unit will not operate while a safety
interlock switch is open. As a temporary
measure during this procedure, defeat the
door interlock switch by inserting one
of the switch keys that shipped with the
unit.
Perform only when the unit is
RUNNING.
Use extreme caution.
Make sure the compressed air supply to
the unit is ON.
Turn power ON at the main disconnect
switch and start the unit.
Test mode can only be entered if the
spread/feed system is off. Make sure no
STATION button is lit and the CHI Panel
display reads FEEDER OFF.
1.
2.
3.
4.
5.
6.
7.
Press and hold the TEST button; then,
press the ENTER button. Release both
buttons. The SELECT TEST menu dis-
plays as follows:
SELECT TEST
INL TRN SPR FEED IRN CHI
The flashing cursor is under INL.
Press the CURSOR button until the flash-
ing cursor is under the desired adjustment
area:
INL is used to test the two pneumatic
clutch-brakes. See
Inlet Section Test
.
TRN is used to test the rodless air cyl-
inder and transfer clamp air cylinders.
See
Transfer Section Test
.
SPR is used to test the upper and
lower spreaders. See
Spreader Sec-
tion Test
.
FEED is used to test the spread clamp
air cylinders and the air bar blast. See
Discharge Section Test
.
IRN and CHI have no associated tests.
They appear for display purposes
only.
Press the ENTER button. The test function
menu displays.
The numbers in the display correspond to
the control output LEDs that trigger with
each operation. Each of the following
sections has a table to use as a guide in
running the test.
The control system automatically begins
to operate each of the components in-
volved in the test.
8.
9.
•
•
•
•
•
10.
11.
Summary of Contents for King Edge
Page 1: ...KING EDGETM Large Piece Spreader Feeder INSTRUCTION MANUAL...
Page 66: ......
Page 122: ......
Page 182: ......
Page 200: ......
Page 202: ......
Page 207: ...5 King Edge PL 3038 008M This Page Blank on Purpose...
Page 240: ...38 PL 3038 008M King Edge This Page Left Blank On Purpose...
Page 260: ...2...
Page 262: ...4...
Page 264: ...6...
Page 266: ...8 C...
Page 268: ...10...
Page 270: ...12...
Page 272: ...14...
Page 274: ...16...
Page 276: ...18...
Page 277: ...19...
Page 278: ...20...
Page 280: ...22...
Page 281: ...23...
Page 282: ...24...
Page 284: ...Skyline S1 S20 Installation...
Page 285: ......
Page 286: ...Skyline S1 S20 Installation...
Page 288: ......
Page 290: ......