King Edge
Troubleshooting
6-15
WARNING
Only trained personnel with experience
in electrical or mechanical repair should
troubleshoot and repair the unit.
Troubleshooting
WARNING
Read the
REPAIR
chapter and make
sure that the power is disconnected
before doing any repairs.
ISSUE
POSSIBLE CAUSE
SOLUTION
Station Carriage Does Not
Clamp and Transport Flatwork
1. CB11 is tripped, CON4 is
bad, CB8 is tripped, T8 is
bad, or CR5 is bad.
Reset and/or test and replace com-
ponent as necessary.
•
2. Sensor PE31 (Station 1) or
PE35 (Station 2) not func-
tioning properly.
Check. For more information within
this chapter, refer to
Sensor Func-
tion
section,
Sensor Function
Issue
issue.
•
3. Carriage down proximity
sensor PX32 (Station 1)
or PX36 (Station 2) not
functioning.
Check. For more information within
this chapter, refer to
Sensor Func-
tion
section,
Proximity Sensor Not
Working
issue.
•
4. Carriage clamp air cylinder
malfunction.
Check. For more information within
this chapter, refer to
Compressed
Air System
section.
•
5. Solenoid fuse on circuit
board is burned out.
Check/replace fuse on MPC1
prefeeder board.
•
6.Carriage drive belt slipping
or broken.
Check condition/tension of belt. Re-
pair/retension or replace as neces-
sary.
•
7. Carriage drive motor/in-
verter problem.
Check. Repair/replace as necessary.
•
Station Carriage Continually
Goes Up and Down
1. Photosensor or connector
is bad.
Check PE31, PE35 as appropriate.
Repair/replace as necessary.
•
Flatwork Stops at the Inlet
Transfer Pickup Clamps
1. Carriage up proximity
sensor PX33 (Station 1)
or PX37 (Station 2) not
functioning.
Check. For more information within
this chapter, refer to
Sensor Func-
tion
section,
Proximity Sensor Not
Working
issue.
•
2. Inlet transfer pickup
proximity sensor PX9 not
functioning.
Check. For more information within
this chapter, refer to
Sensor Func-
tion
section,
Proximity Sensor Not
Working
issue.
•
3. Transfer rodless air cylin-
der malfunction.
Check. For more information within
this chapter, refer to
Compressed
Air System
section.
•
4. Solenoid fuse on circuit
board is burned out.
Check/replace fuse on MPC1
prefeeder board.
•
6.5 Prefeed/Inlet Section
Summary of Contents for King Edge
Page 1: ...KING EDGETM Large Piece Spreader Feeder INSTRUCTION MANUAL...
Page 66: ......
Page 122: ......
Page 182: ......
Page 200: ......
Page 202: ......
Page 207: ...5 King Edge PL 3038 008M This Page Blank on Purpose...
Page 240: ...38 PL 3038 008M King Edge This Page Left Blank On Purpose...
Page 260: ...2...
Page 262: ...4...
Page 264: ...6...
Page 266: ...8 C...
Page 268: ...10...
Page 270: ...12...
Page 272: ...14...
Page 274: ...16...
Page 276: ...18...
Page 277: ...19...
Page 278: ...20...
Page 280: ...22...
Page 281: ...23...
Page 282: ...24...
Page 284: ...Skyline S1 S20 Installation...
Page 285: ......
Page 286: ...Skyline S1 S20 Installation...
Page 288: ......
Page 290: ......