CHC
CTS-112R4 user manual
89
13.
Parameters
You can set unit and measuring mode in the menu of PARAMETERS, in MENU press
”
5
”
to enter
PARAMETERS.
Unit Set
Name
Description
FEET:
Select the standard of FEET.
International feet: 1m=3.280839895013123ft
USA feet: 1m=3.2803333333333ft
ANGLE:
Select angle unit. DEG/GON/MIL (degree/gon/mil)
DISTANCE:
Select distance unit: m / ft / ft+in(meter/feet/feet∙inch)
TEMP. & PRESS:
Select temperature unit:
o
C /
o
F
Select pressure unit: hPa /mmHg/inHg
Mode set
Name
Description
POWER ON MODE:
Choose to enter angle, distance or coordinates measuring mode after power on
DIST. MODE:
Choose the distance mode after power on, fine[s], fine[n], fine[r], or tracking
NEZ/ENZ:
Choose the coordinates displaying order NE/Z or EN/Z
V.ANGLE Z0/H0:
Choose the reading of vertical angle, from zenith or horizontal.
Other set
Name
Description
Min angle read:
Set the minimum reading of angle unit
Min Dist read:
Set the minimum reading of distance unit
Face in L or R:
Set auto power off ON: If NO key is pressed or no measurement is launched in
30 minutes, the total station will be off automatically
Auto power off:
Set auto power off ON: If NO key is pressed or no measurement is launched in
30 minutes, the total station will be off automatically
H-Angle buzzer:
When the horizontal angle exceeds 90°, whether the buzzer is activated
Meas buzzer:
When there’s reflecting signal, whether the buzzer is activated
W-correction:
Settings of atmospheric refraction and curvature correction
Date&Time:
Set the date and time
COMM.PARAMETERS:
Set RS-232C parameters
GRID FACTOR:
Set grid factor