CHC
CTS-112R4 user manual
69
3)
Input INS.HT and press [F4] ENT.
4)
Press [F3] or [F4] to choose whether need to set backsight.
5)
Press [ENT], success to call out file, and then the screen returns to DATA COLLECT MENU 1/2.
11.2.4.
Setting backsight point
The following three setting methods for Backsight point can be selected:
•
Setting from the coordinate data file stored in the internal memory.
•
Direct input of coordinate data.
•
Direct input of setting angle.
Example: Setting the backsight point from the internal coordinate data file
1)
Press [2] (BACKSIGHT) in LAYOUT menu.
2)
Press [1](BS COORD).
3)
Display the coordinate of this point. Press [F4] (YES) and the display shows the azimuth.