CHC
CTS-112R4 user manual
36
5)
Procedure: aim to target B by rotating the horizontal clamp and tangent screws, and press [F4]
(HOLD).
Operation: collimate B [F4]
6)
Procedure: aim A again by adjusting horizontal clamp and tangent screws and press F3] (REL).
Operation: collimate A [F3]
7)
Procedure: aim B again and press [F4] (HOLD).
Operation:
collimate B [F4]
8)
Procedure: Repeat procedure 6 and 7 until desired times of measurement are finished. E.g. repeat 6
times.
9)
Procedure: to quit the repetitious angle measurement, press [F2] (EXIT) and press [F4] (YES) to
return to normal angle measurement mode.
Operation: [F2] [F4]
Horizontal angle can be totaled from 3600°00′00″to minimum reading. Under horizontal right
angle: E.g.: when minimum reading is 5”, horizontal angle can be totaled to ±3599°59′55″.
When the difference between the measured angle result and the first result exceed ±30″,
then an error message will show.