6 - MAINTENANCE
Radiator fan
Visual inspect the radiator fan daily, check every
500 h
1. Rotate the crankshaft by using the engine barring
gear. Check for cracks, loose rivets, and bent or loose
blades.
NOTE:
never pull or pry on the fan.
2. Check the fan to make sure it is securely mounted.
3. Tighten the cap-screws if necessary. If the fan is dam-
aged, consult your CASE CONSTRUCTION dealer to
replace the fan.
SMIL16MEX0436AA
1
Travel reduction gears
Check the travel reduction gears oil level every
500 h
.
Lubricant:
CASE AKCELA GEAR 135 H EP 80W-90
1. Park the machine on flat, horizontal ground.
2. Move the machine so that the drain plug
(1)
comes
down to the lowest position.
3. Stop the engine and remove the starter key.
4. Remove the level plug
(2)
, and check the oil level. If
the level comes up to the bottom edge of port
(2)
, it is
sufficient.
If necessary, add oil through port
(2)
until the oil comes
up to the bottom edge of port
(2)
.
5. Check the O-ring seal of the level plug
(2)
for damages,
and replace it if necessary.
6. Insert the level plug
(2)
with seal tape wrapped around
it.
7. Repeat Steps
2
to
6
for the other travel reduction gear.
8. Run the machine slowly to check that there are no
leaks.
SMIL16MEX1456AB
1
6-44