![CASE CONSTRUCTION CX37C Operator'S Manual Download Page 177](http://html1.mh-extra.com/html/case-construction/cx37c/cx37c_operators-manual_2567477177.webp)
6 - MAINTENANCE
3. Remove the cover
(2)
of the air cleaner
(3)
.
SMIL16MEX1530AA
3
4. Remove the primary element
(4)
.
5. Clean the primary element
(4)
.
SMIL16MEX1531AA
4
When the primary element is dry:
Blow compressed air at very low pressure from the in-
side to the outside.
Hold the compressed air nozzle at a position at least
3 cm
(
1.181 in
) away from the inside wall of the ele-
ment. When no more dust comes out of the primary
element, cleaning is complete.
NOTE:
be sure to keep the compressed air pressure below
3 bar
(
44 psi
).
SMIL14CEX2795AA
5
NOTE:
do not use compressed air if there is oil or soot in
the element.
If the cartridge is greasy:
Clean it in water, with suitable detergent. (Consult your
CASE CONSTRUCTION dealer).
Instructions for using the detergent are printed on the
package.
NOTE:
dry the element out completely before installing it.
It is advisable to keep a clean spare element ready that can
be installed on the air cleaner while the cleaned element is
drying.
SMIL13CEX2757AA
6
6-41
Summary of Contents for CX37C
Page 16: ...1 GENERAL INFORMATION 1 10...
Page 64: ...3 CONTROLS AND INSTRUMENTS Footrest SMIL16MEX1264BA 17 3 12...
Page 136: ...5 TRANSPORT OPERATIONS 5 8...
Page 200: ...6 MAINTENANCE 6 64...
Page 204: ...7 TROUBLESHOOTING 7 4...