96
▶
SPECIFICATIONS
Output
Precision
Max. Impedance
V-OUT
0~10V(DC)
Over 1/1000
-
I-OUT
0~24mA
Over 1/1000
500Ω MAX
▶
V-out Equivalent Circuit
▶
I-out Equivalent Circuit
※
V-out output puts out Analog voltages(0~10V) proportional to the signal input displaying the weight
※
I-out output is adjusted so as to be 4 mA when the weight display is 0, and 20 mA when it is the
maximum load,
▶
Lo(-) terminal is not GND, it should not be connected to GND line or body GND of of some other
equipment or similar apparatus
▶
Adjust F4-01, F4-02 if the range of the output values needs to be adjusted.