63
Weighing Output Information per Mode
Relay Mode
OUT 1
OUT 2
OUT 3
OUT 4
OUT 5
OUT 6
0_Limit Mode1
Step 1
(SP1 ≤ W)
Step 2
(SP2 ≤ W)
Step 3
(SP3 ≤ W)
Step 4
(SP4 ≤ W)
Completed
Zero
1_Limit Mode2
Step 1
(SP1-SP3 ≤ W)
Step 2
(SP2-SP4 ≤ W)
Completed
Lower
Limit NG
(W < SP2-SP6)
Upper
Limit NG
(SP2+SP5 <
W)
Zero
2_Packer Mode1
Step 1
(W ≤ SP1)
Step 2
(W ≤ SP2)
Step 3
(W ≤ SP3)
Step 4
(W ≤ SP4)
Completed
Zero
3_Packer Mode2
Step 1
(W≤ SP1-SP3)
Step 2
(W≤ SP2-SP4)
Completed
Lower
Limit NG
(W < SP2-SP6)
Upper
Limit NG
(SP2+SP5 <
W)
Zero
4_Checker Mode1
Step 1
(Z ≤ W < SP1)
Step 2
(SP1 ≤ W <
SP2)
Step 3
(SP2 ≤ W <
SP3)
Step 4
(SP3 ≤ W <
SP4)
Above
Step 4
Zero
5_Checker Mode2
Step1 : LOW
(Z ≤ W < SP1)
Step2 : HIGH
(SP2 ≤ W)
Step3 : OK
(SP1 ≤ W <
SP2)
Lower
LimitNG
(Z ≤ W < SP1)
Upper
LimitNG
(SP2 ≤ W)
Zero
6_Checker Mode3
Step 1
(Z ≤ W < SP1)
Step 2
(SP1 ≤ W <
SP2)
Step 3
(SP2 ≤ W <
SP3)
Step 4
(SP3 ≤ W <
SP4)
Above
Step4
(SP4 ≤ W)
Zero
7_Checker Mode4
Step1 : LOW
(Z ≤ W < SP1)
Step2 : HIGH
(SP2 ≤ W)
Step3 : OK
(SP1 ≤ W <
SP2)
Lower
LimitNG
(Z ≤ W < SP1)
Upper
LimitNG
(SP2 ≤ W)
Zero
8_Checker Mode5
Step1 : LOW
(Z ≤ W < SP1)
Step2 : HIGH
(SP2 ≤ W)
Step3 : OK
(SP1 ≤ W <
SP2)
Lower
LimitNG
(Z ≤ W < SP1)
Upper
LimitNG
(SP2 ≤ W)
Zero
9_Auto Tare
Packer Mode
Step 1
(W≤ SP1-SP3)
Step 2
(W≤ SP2-SP4)
Completed
Lower
Limit NG
(W < SP2-SP6)
Upper
Limit NG
(SP2+SP5 <
W)
Zero
10_Auto Tare
Auto Packer Mode
Step 1
(W≤ SP1-SP3)
Step 2
(W≤ SP2-SP4)
Completed
Lower
Limit NG
(W < SP2-SP6)
Upper
Limit NG
(SP2+SP5 <
W)
Zero
11_Auto Zero
Auto Packer Mode
Step 1
(W≤ SP1-SP3)
Step 2
(W≤ SP2-SP4)
Completed
Lower
Limit NG
(W < SP2-SP6)
Upper
Limit NG
(SP2+SP5 <
W)
Zero
Summary of Contents for CI-400 Series
Page 1: ... 2 ...
Page 10: ...11 2 Specifications in Appearance 2 1 External Dimension ...
Page 29: ... 30 4 2 How to Seal the Indicator Sealing ...
Page 93: ... 94 Connection of Input Output Input AContact Output AContact ...
Page 117: ... 118 MEMO ...
Page 118: ...119 MEMO ...
Page 119: ... 120 MEMO ...
Page 120: ...121 ...