25
CAL 4(Hopper weight setting)
CAL 4-1
Function: Setting Multi Calibration Step
Range of set value: 2 ~ 5
Used key
Display
Descriptions
Using numeric keys
~
Set the range.
= Set,
=Cancel
STEP- 2
Setting multi calibration for step 2
(for hopper system)
STEP- 5
Setting multi calibration for step 5
(for hopper system)
CAL 4-2
Function: Setting Weight
Range of set value: 1 ~ 99,999
Used key
Display
Descriptions
Using numeric keys
~
Set the counterweight values
= Set,
=Cancel
LOAD 1
It means the weight setting mode.
(Number = multi calibration number)
W=100.00
100.00 (unit: Kg or Ton)
W= 0.10
0.10 (unit: Kg or Ton)
Reference 1. Set the counterweight within 10~100% of the maximum capacity
CAL 4-3
Function: Weight Calibration
Used key
Display
Descriptions
= Set,
=Cancel
LoAd
Load the weight set in CAL 4-3 and press
the setup key.
12345
The current weight value is displayed.
Confirm 'Stable' and press the setup key.
- - -
Span adjustment in progress...
Reference 1. Repeat 'CAL4-2' , 'CAL4-3' according to the number of STEPs set in 'CAL 4-1'.
At this instance the weight value should be calibrated to be greater than the previous values.
Reference 2. If the span calibration is completed without error, it will advance to CAL-4.
Summary of Contents for CI-400 Series
Page 1: ... 2 ...
Page 10: ...11 2 Specifications in Appearance 2 1 External Dimension ...
Page 29: ... 30 4 2 How to Seal the Indicator Sealing ...
Page 93: ... 94 Connection of Input Output Input AContact Output AContact ...
Page 117: ... 118 MEMO ...
Page 118: ...119 MEMO ...
Page 119: ... 120 MEMO ...
Page 120: ...121 ...