CAL 3-3
Function: Setting Weight
Range of set value: 1 ~ 99,999
Used key
Display
Descriptions
Using numeric keys
~
Set the counterweight values
= Set,
=Cancel
LOAD 1
It means the weight setting mode.
(Number = multi calibration number)
W=100.00
100.00 (unit: Kg or Ton)
W= 0.10
0.10 (unit: Kg or Ton))
Reference 1. The counterweight should be set within 10~100% of the maximum capacity.
CAL 3-4
Function: Weight Calibration
Used key
Display
Descriptions
= Set,
=Cancel
LoAd
Load the weight set in CAL 4-3 and press
the setup key.
12345
The current weight value is displayed.
Confirm 'Stable' and press the setup key.
- - -
Span adjustment in progress...
Reference 1. Repeat 'CAL3-3' and 'CAL3-4' according to the number of STEPs set in 'CAL 3-1'.
At this instance, the weight value must be set to be greater than the previous values.
Reference 2. If the span calibration is completed without any error, "SUCCESS" will be displayed and will advance to
the weight verification mode.
Reference 3. If there are no problems after weight verification, pressing
key will move to 'CAL 3'.