SECTION 6
MESSAGECENTER MESSAGES
6.1
MESSAGECENTER MESSAGES
The following table lists all of the messages which do not appear in other lists in this manual and a description of
their meaning. Refer to
for a list of Alarm messages. Refer to
sages. Refer to
for a list of Functional Parameter messages. Refer to
for a list of Con-
figuration messages.
Table 6–1 MessageCenter Messages
Message
Description
ACTIVE
This message will appear in the MessageCenter along with the current
IntelliSet indicating that the IntelliSet is active and none of its settings
have been modified.
ACTIVE ALARM LIST CLEARED
The list of active alarms in the microprocessor has been erased. (This
does
not
remove alarms from the DataLink data recorder.)
ALL ALARMS CLEARED
The list of active and inactive alarms in the microprocessor alarm lists
have been erased. (This does
not
remove alarms from the DataLink data
recorder.)
BUZZER OFF IN X MINS
The Buzzer circuit has been energized in Component Test Mode. The
Buzzer circuit will continue to be energized for the number of minutes
shown.
CANNOT ENTER TRIP START
Cannot enter Trip Start. A problem has been detected within the DataLink
data recorder.
CANNOT START DEFROST CYCLE
Due to current unit conditions, the defrost cycle cannot be started. Refer
to Defrost
and
.
CANNOT START PRETRIP
Due to current unit conditions a Pretrip test cannot be started. Re- fer to
Pretrip
CHANGE INTELLISET TO EXIT
The IntelliSleep IntelliSet is active. Alternates with “INTELLI
−
SLEEP
MODE” at 5 second interval whether unit is running or not.
CHARGE MODE
−
HOLD = TO EXIT
Service Mode has the refrigeration system set so that it can be charged
with refrigerant through the liquid line service valve. Press the = key to
manually exit, or wait until the charging is complete.
CHECK AT NEXT SERVICE INTER-
VAL
The unit needs to be checked at next service interval.
There is currently an active non
−
shutdown alarm in the alarm list.
CHECK DOOR
The door switch indicates that a refrigerated compartment door is not
closed.
CHECK FUEL LEVEL (Requires Op-
tional Sensor)
The level in the fuel tank is very close to empty.
COMPONENT TEST MODE
Pressing the = key while this message is highlighted will allow user ac-
cess to Component Test Mode.
CONTINUOUS LOCKED
The current setpoint is within a range that has been locked into the Con-
tinuous Run Mode. Start
−
Stop can not be selected.
CONTINUOUS RUN MODE SELECT-
ED
The unit operating mode has been changed from Start-Stop to Continu-
ous Run.
DATA RECORDER FAILURE
The microprocessor has stopped recording Unit Data.
DEFROST CYCLE STARTED
The unit has gone into defrost.