6–3
62-11637
PRETRIP PASS
All of the Pretrip tests were ok.
PRETRIP STOPPED BY USER
Pretrip has been stopped by user.
PRODUCTSHIELD: ECONO ON
The unit is operating in ProductShield Econo which overrides normal unit
Start
−
Stop or Continuous Run operation. Refer to
PRODUCTSHIELD: HIGH AIR ON
The unit is operating in ProductShield High Air which overrides normal
unit speed operation. Refer to
.
PRODUCTSHIELD: WINTER ON
The unit is operating in ProductShield Winter which overrides normal unit
operation. Refer to
.
RECORDING DATA
−
PLEASE WAIT
MICRO WILL RESTART WHEN COM-
PLETE
This message will be displayed when the unit is starting and the main mi-
croprocessor is completing communicating with another module.
RECOVER / LEAK CHK / EVAC MODE This message will be displayed when the unit is in Service Mode and the
system is ready for recovery and leak testing.
REMOTE SWITCH 1 OPEN
Remote switch is open. May be connected to a refrigerated compartment
door or a remote control switch.
REMOTE SWITCH 1 OPEN
−
LOW
SPEED
Shows that the remote switch is open and that the unit is running in low
speed. Switch may be connected to a refrigerated compartment door or
a remote control switch.
SERVICE MODE
Selection which is used when servicing the refrigeration system. Refer to
.
SETPOINT CHANGED
The new setpoint has been entered (saved into microprocessor memo-
ry), the new setpoint will be used.
SETPOINT NOT CHANGED
The new setpoint has NOT been entered (NOT saved into micro- proces-
sor memory), the old setpoint will be used.
SETTING SMV: XXX %
The START/RUN
−
OFF switch has been toggled out of the OFF position
and the CSMV is opening.
SLEEP MODE, OFF / ON TO WAKE
The unit is cycled off in Sleep Mode. Place the START/RUN
−
OFF switch
in the OFF position, then back to the START/RUN position to wake the
microprocessor up.
SLEEP WARNING: DOOR OPEN
The unit is configured for Rail Mode and the unit is in Sleep Mode and a
refrigerated compartment door is open. The unit will start as needed for
Sleep Mode.
SLEEP WARNING: NO TEMP CON-
TROL
The unit is running in Sleep Mode to charge the battery and (in Engine
Operation) warm the engine coolant. It is not running to provide tempera-
ture control.
SLEEP WARNING: REMS1(2) OPEN
The unit is configured for Rail Mode and the unit is in Sleep Mode and a
remote switch is open. The switch may be connected to a refrigerated
compartment door or to a remote control switch. The unit will start as
needed for Sleep Mode.
SMV CLOSING: WAIT XXX SECONDS Power Up and the CSMV is closing. XX indicates the number of seconds
remaining until valve is fully closed.
START STOP LOCKED
The setpoint has been locked into Start
−
Stop Operation. Continuous Run
can not be selected.
START
−
STOP MODE SELECTED
Start
−
Stop Operation has been selected.
STATUS OK
The unit is operating correctly.
Table 6–1 MessageCenter Messages