![background image](http://html1.mh-extra.com/html/carrier/transicold-x4-7300/transicold-x4-7300_operation-and-service-manual_2564193111.webp)
5–21
62-11637
ENGINE SETTINGS
GLOW TIME
SHORT
LONG
INTAKE HEATER
Indicates to the main microprocessor which engine
is in the system.
LONG = Glow Plug equipped and longer glow times
are used (TV engines).
SHORT= Glow Plug equipped and shorter glow
times are used (DI engines).
INTAKE HEATER = Engine preheat equipped (Tier
4 engines).
NOTE: Refer to
ENGINE OIL LEVEL
SWITCH
YES /
NO
Use of an oil level device is not recommended at this
time.
USE FACTORY DEFAULT SETTING ONLY, DO
NOT OPERATE UNIT WITH DIFFERENT SETTING.
ENGINE OIL LEVEL SHUT-
DOWN
YES /
NO
YES = When the A00002 - “LOW ENGINE OIL LEV-
EL” alarm is activated the alarm light will illuminate
and the unit will shut down.
NO = When the A00002 - “LOW ENGINE OIL LEV-
EL” alarm is activated the alarm light will illuminate
and the unit will continue to run.
HIGH ENGINE TEMP
SHUTDOWN
YES /
NO
YES = When the A00012 - “High Coolant Tempera-
ture“ alarm has been activated three times in the last
two hours of engine operation the A00021 - Techni-
cian Reset Required” alarm will be activated.
NO = When the A00012 - “High Coolant Tempera-
ture“ alarm has been activated three times in the last
two hours of engine operation the A00021 - Techni-
cian Reset Required” alarm will not be activated.
ENGINE OIL PRESS
SHUTDOWN
YES /
NO
YES = When the A00011 - “Low Engine Oil Pres-
sure“ alarm has been activated three times in the last
two hours of engine operation the A00021
−
“Tech-
nician Reset Required“ alarm will be activated.
NO = When the A00011 - “Low Engine Oil Pressure“
alarm has been activated three times in the last two
hours of engine operation the A00021
−
“Technician
Reset Required“ alarm will not be activated.
FUEL LEVEL SENSOR
YES /
NO
NO = There is no Fuel Level Sensor installed in the
fuel tank.
YES = A Low Fuel Level Sensor is installed in the
fuel tank.
• LOW FUEL ALARM
UNIT SHUTDOWN
ALARM ONLY
UNIT SHUTDOWN = The unit will be shutdown and
alarm if level reaches 15%.
ALARM ONLY = An alarm will be generated if level
reaches 15% and the engine will continue to run.
FUEL HEATER
NOT INSTALLED
INSTALLED
NOT INSTALLED = A Fuel Heater is not installed.
INSTALLED = A Fuel Heater is installed.
Table 5–1 Configuration Settings
Configuration
Selections
Description
Summary of Contents for Transicold X4 7300
Page 21: ...62 11637 1 6 1 3 SAFETY DECALS ...
Page 22: ...1 7 62 11637 62 03958 ...
Page 23: ...62 11637 1 8 ...
Page 24: ...1 9 62 11637 ...
Page 119: ...62 11637 SECTION 6 MESSAGECENTER PARAGRAPH NUMBER Page 6 1 MESSAGECENTER MESSAGES 6 1 ...
Page 278: ......