![background image](http://html1.mh-extra.com/html/carrier/transicold-x4-7300/transicold-x4-7300_operation-and-service-manual_2564193176.webp)
62-11637
7–50
P00144
CHECK UL1 CIRCUIT
• ACTIVATION: The circuit current draw is outside the normal range.
• UNIT CONTROL: Pretrip will fail in test 2 and display “PRETRIP FAIL AND COMPLETED”.
• RESET CONDITION: Auto reset if Pretrip is started again, or alarm may be manually reset using the dis-
play mounted keys or by turning the unit off, then back on again.
CORRECTIVE ACTIONS:
1.
Check UL1 Operation
Refer to procedure for alarm
. Alarm condition must be corrected and the
alarm cleared to continue.
P00148
CHECK SV1 CIRCUIT
• ACTIVATION: The circuit current draw is outside the normal range.
• UNIT CONTROL: Pretrip will fail in test 2 and display “PRETRIP FAIL AND COMPLETED”.
• RESET CONDITION: Auto reset if Pretrip is started again, or Alarm may be manually reset using the dis-
play mounted keys or by turning the unit off, then back on again.
CORRECTIVE ACTIONS:
1.
Check SV1 Operation
Refer to procedure for alarm
. Alarm condition must be corrected and the
alarm cleared to continue.
P00150
CHECK SV4 CIRCUIT
• ACTIVATION: The circuit current draw is outside the normal range.
• UNIT CONTROL: Pretrip will fail in test 2 and display “PRETRIP FAIL AND COMPLETED”.
• RESET CONDITION: Auto reset if Pretrip is started again, or Alarm may be manually reset using the dis-
play mounted keys or by turning the unit off, then back on again.
CORRECTIVE ACTIONS:
1.
Check SV4 Operation
Refer to procedure for alarm
. Alarm condition must be corrected and the
alarm cleared to continue.
P00151
CHECK GLOW CIRCUIT (This applies to the engine preheater = EPH)
• ACTIVATION: The circuit current draw is outside the normal range.
• UNIT CONTROL: Pretrip will fail in test 2 and display “PRETRIP FAIL AND COMPLETED”.
• RESET CONDITION: Auto reset if Pretrip is started again or alarm may be manually reset using the dis-
play mounted keys or by turning the unit off then back on again.
CORRECTIVE ACTIONS:
1.
Check Glow Plug Operation
00040 CHECK ENGINE PREHEAT CIRCUIT
. Alarm condition must be
corrected and the alarm cleared to continue.