62-11637
6–4
TECHNICIAN RESET REQUIRED
(AL00021)
AL00011 (Low Engine Oil Pressure) or AL00012 (High Coolant Tempera-
ture) has been activated three times in the last two hours and the unit has
been locked out. Refer to
for further information.
TIME SELECTION NOT CHANGED
A time change was started but not entered (saved) in Configuration List.
TRIP START ENTERED
The Trip Start marker has been placed in the DataLink data recorder.
UNIT BATTERY TOO LOW
The unit battery has dropped below 7 volts for more than 10 seconds.
UNIT SHUTDOWN
−
DOOR OPEN
The unit has shutdown because the refrigerated compartment door is
open.
UNIT SHUTDOWN
−
SEE ALARM
LIST
An active shutdown alarm has shut the unit down.
UNIT SHUTDOWN
−
RMS1
The unit has shutdown because switch is open. May be connected to a
door or a remote control switch.
USE UP/DOWN KEY TO SCROLL USE
= KEY TO SELECT ITEM TO CHANGE
Items available are being displayed or additional items are available for
selection. Use the up or down arrow key to highlight or display and high-
light the desired selection and then use the “=” key to select it.
VIEWING MENU SOFTKEY SELEC-
TIONS PRESS MENU KEY TO
SCROLL
Additional soft key selections are available and the MENU key is to be
used to scroll and view them.
WARNING: NO TEMP CONTROL
The temperature sensors have failed and the unit has entered Cargo Pro-
tect Mode. Refer to
Table 6–1 MessageCenter Messages
Message
Description
Summary of Contents for Transicold X4 7300
Page 21: ...62 11637 1 6 1 3 SAFETY DECALS ...
Page 22: ...1 7 62 11637 62 03958 ...
Page 23: ...62 11637 1 8 ...
Page 24: ...1 9 62 11637 ...
Page 119: ...62 11637 SECTION 6 MESSAGECENTER PARAGRAPH NUMBER Page 6 1 MESSAGECENTER MESSAGES 6 1 ...
Page 278: ......