62-11637
2–16
2.9
REFRIGERATION SYSTEM DATA
2.10 COMPONENT RESISTANCE & CURRENT DRAW
2.11 SAFETY DEVICES
The system is protected from high pressure conditions which may occur when exposed to very high temperatures
(such as a fire) by a fusible plug mounted in the receiver. Under very high temperature conditions (refer to
) the plug will melt, releasing the refrigerant pressure.
System components are protected from damage caused by unsafe operating conditions by automatic shut-down of
the unit when such conditions occur. This is accomplished by the safety device listed in the following table and the
fuses shown in
.
Unit
Specification
Defrost Air Switch (DAS)
Initiates Defrost: 1.40 ± .07 inch (35 ± 1.8 mm) WG
Defrost Timer
1.5h, 3h, 6h, or 12 hours
Fusible Plug Melting Point
430°F (221°C)
High Pressure Switch (HPS)
Opens, on pressure rise, at: 465 ± 10 psig (32 ± 0.7 bar)
Closes, on pressure fall, at: 350 ± 10 psig (24 ± 0.7 bar)
Unit Dry Weight, Less Battery
X4 7300 = 1610 (730 KG) X4 7500 = 1620 pounds (735 KG)
Battery
50 pounds (23 KG.)
Fan Clutch Air Gap
0.011 to 0.085 inch (0.28 to 2.2 mm)
Refrigerant Charge
Gearbox Oil
Mobil Delvac 75-90W: 15oz (0.44 liters)
Fanshaft Oil
Mobil SHC 630: 2.8oz (0.08 liters)
Component
Ohms
Amps
AutoFresh Air Exchange Relay (AFAR)
97 Ohms between pins 1 & 2
AutoFresh Air Exchange (AFAS)
Pull in - 0.36 Ohms ± 10%
Hold - 14.4 Ohms ± 10%
Pull in - 29 Amps
Hold - 0.83 Amps
Clutch (CLH)
2.5 ± 0.2 Ohms
3.0 to 5.0 Amps
Condenser Pressure Control Solenoid Valve (SV1) 7.8 ± 0.3 Ohms
0.7 to 2.0 Amps
Engine Preheater (EPH)
0.3 to 0.5 Ohms
38 - 46 Amps
Engine Speed Sensor (ENSSN)
22 mAmps Max
Fuel Heater (FH)
Standard
0.96 Ohms ± 10%
12.5 amps ± 10%
Suction Side
1.3 Ohms ± 10%
10.7 amps ± 10%
Fuel Heater Relay (FHR) and Power Enable Relay
(PER)
90 Ohms between pins 85 & 86
Fuel Pump (FP)
11.5 Ohms ± 10%
1.4 Amps @ 16 VDC
Fuel/Speed Actuator (FSA)
2.8 Ohms ± 10% @68°F (20°C)
4 Amps Max
Liquid Line (SV2) and Hot Gas (SV4) Solenoid
Valve
10.6 ± 0.3 Ohms
0.75 to 2.0 Amps
Starter Motor (SM)
Less than 1 Ohm but more than 0
270 - 380 amps
Unloader Solenoid Valve (UL1 & UL2)
9.6 ± 0.8 Ohms
1.0 to 2.0 Amps
Unsafe Conditions
Safety Device
Device Setting
Excessive operating pressure
High Pressure Switch (HPS)
Summary of Contents for Transicold X4 7300