ALTERNATOR CHECK
SHUTDOWN
YES /
NO
YES = When the A00051 - “ALTERNATOR NOT
CHARGING” alarm is activated the alarm light will il-
luminate and the unit will shut down.
NO = When the A00051 - “ALTERNATOR NOT
CHARGING” alarm is activated the alarm light will il-
luminate and the unit will continue to run.
CONFIGURE HOUR METERS
VIEWABLE STANDARD METERS
DISPLAY TOTAL ENGINE
HR
YES
/ NO
YES = This hour meter will be displayed during the
startup messaging sequence and will be in hour me-
ter menu.
NO = This hour meter will not be displayed during the
startup messaging sequence. It will be displayed
with the “other meters and counters”.
DISPLAY TOTAL SWITCH
ON HR
YES
/ NO
YES = This hour meter will be displayed during the
startup messaging sequence and will be in hour me-
ter menu.
NO = This hour meter will not be displayed during the
startup messaging sequence. It will be displayed
with the “other meters and counters”.
SET PM CONFIGURATIONS
PM (METER NUMBER)
CONFIGS
Meters available are PM
−
1
thorough PM
−
5.
OFF
HIGH SPEED HOURS
START CYCLES
CLUTCH CYCLES
SWITCH ON HOURS
ENGINE HOURS
OFF = This selection will turn this meter OFF (will not
display).
ENGINE HOURS = this meter will count the engine
hours until the next reset interval.
SWITCH ON HOURS = this meter will count the
switch on hours until the next reset interval.
START CYCLES = this meter will count how many
times the engine has started until the next reset in-
terval.
CLUTCH CYCLES = this meter will count how many
times the clutch is engaged until the next reset inter-
val.
HIGH SPEED HOURS = this meter will count the
number of hours the engine operated in high speed
until the next reset interval.
If a meter is configured, the following sub
−
configura-
tion will be available.
DIESEL RESET VALUE
(Refer to
for oil/
filter change intervals.)
OFF
50 to 30,000 hours in 50 hour
increments
When the engine maintenance hour meter is reset,
the value selected here will be added to the present
meter reading to indicate to the microprocessor
when the next service interval alarm will be activat-
ed. If the value entered is “0” the alarm feature is
turned off.
Table 5–1 Configuration Settings
Configuration
Selections
Description
Summary of Contents for Transicold X4 7300
Page 21: ...62 11637 1 6 1 3 SAFETY DECALS ...
Page 22: ...1 7 62 11637 62 03958 ...
Page 23: ...62 11637 1 8 ...
Page 24: ...1 9 62 11637 ...
Page 119: ...62 11637 SECTION 6 MESSAGECENTER PARAGRAPH NUMBER Page 6 1 MESSAGECENTER MESSAGES 6 1 ...
Page 278: ......