62-11637
3.3
STARTING
WARNING
!
Under no circumstances should ether or any other starting aids be used to start the engine.
1. Place the START/RUN-OFF switch in the
START/RUN position.
2. The system will display the Carrier Transicold
logo, display the default screen, present lan-
guage selection and the hour meter readings (if
configured to do so) along with a test flash of the
alarm light and light bar amber LED’s. The sys-
tem will then perform a start sequence, energize
the buzzer, and then start the unit automatically.
3. If there is an alarm present, the alarm message
will be displayed in the MessageCenter and the
alarm LED will flash for 5 seconds. If one or
more shutdown alarms are present, the alarm(s)
must be cleared before the unit will start.
4. Observe the MessageCenter. If the word
“ACTIVE” or “MODIFIED” is displayed at the
right, the unit is equipped with IntelliSet settings.
Proceed to page 4. If “ACTIVE” or “MODIFIED”
is not displayed, proceed to page 6.
5. If the LCD Display does not illuminate:
• Check the battery voltage. A booster battery
may be needed.
• Check for blown fuse(s).
• Verify the harness connector at the back of
the display module and all other module con-
nectors are securely attached.
3.4
INTELLISET
Products carried or stored in a refrigerated compart-
ment require a multitude of refrigeration unit settings
that must be checked and, if required, reset each time
a new product is loaded. The APX control system
offers the settings necessary to meet these require-
ments. IntelliSet is a feature that allows pre-selection
and naming of the necessary settings for over 40 differ-
ent products. The operator may then call up the set-
tings by simply selecting the assigned IntelliSet name.
For example: A load of apples may require setting the control system for continuous operation at 35°F (1.7°C) with
a defrost every 3 hours while a load of cheese may require the same operation with setpoints ranging from 35°F to
42°F (1.7°C to 5.6°C) and a load of ice cream requires Start-Stop operation at -22°F (-30°C) with defrost at 12 hour
intervals. The settings required for each product may be entered into the control system and then locked so they
cannot be changed. In the case of the load of cheese, the range of setpoints may be locked, leaving the operator
the ability to change the setpoint within the locked range.
OFF
START/RUN
O
I
CONTINUOUS
START/STOP
MENU
ALARM
DEFROST
COOL
DIESEL
START/STOP
STATUS OK
36
36
.2
BOX TEMPERATURE F
SETPOINT F
4
3
1