![background image](http://html1.mh-extra.com/html/carrier/transicold-x4-7300/transicold-x4-7300_operation-and-service-manual_2564193103.webp)
5–13
62-11637
6. With the desired file highlighted, press the “=” key to start the installation. Press any other key to exit and
return to the USB soft keys.
7. The unit will shutdown and the settings will be installed. If a single configuration is installed, the system will
reset and the unit will restart. If IntelliSets are installed, following the system reset, the user will be prompted
to select one of the new IntelliSets before the unit can be started.
5.4
TRU-TECH & TRU-VIEW
The TRU-Tech & TRU-View program allows the user to
access and download data, using a computer, when
the unit is not running and without starting the eight-
hour DataLink data recorder timer. Using the computer
will provide additional programming and configuring
capabilities that will not be available using the display
mounted keys. The DataLink data recorder may also
be configured using the TRU-Tech program.
For complete instructions on using TRU-Tech & TRU-
View, refer to the manual supplied with the TRU
−
Tech/
TRU
−
View software.
NOTE
For diagnoses of problems with the control
system, DataLink data recorder download-
ing, file analysis using TRU
−
View or use of
5.4.1
TRU-Tech
The TRU-Tech Program enables the user to do the fol-
lowing:
• Monitor in real-time via the USB interface port
the current status of the control system inputs,
outputs, refrigeration, electrical, engine and tem-
perature sensors and alarms.
• Record sensor data to a file for diagnostic pur-
poses.
• Display, edit and send unit model number, unit
serial number and trailer ID to the main micro-
processor.
• Display, edit and send Functional Parameters
and Configuration settings to the System (includ-
ing the DataLink data recorder) or to a Data
Transfer USB memory device.
• Write hour meter values to a replacement main
microprocessors (during the first 25 hours).
• Initiate Pretrip and Defrost operations.
• Support Download, Configuration and Program
USB operations.
• Provide a security log on system controlled by a
System Administrator.
5.4.2
TRU–View
The TRU-View Program enables the user to do the fol-
lowing:
• Read download files from the System.
• Create various customized text reports that
include setpoint, sensors, and events.
• Create various customized graphical reports.
• Print numerical, graphical, and event reports.
• View and print refrigeration system historical set-
tings and changes.
• Filter download data by date range and desired
sensors and events.
• Search for a sensor or event of interest.
• Synchronize multiple graphical and numerical win-
dows to better understand historical operation.
• PC Setup enables the user to select how to dis-
play various parameters for use in the graph and
text window.
• Easily adjust x and y axis and color scheme to
accommodate various data.
• Export data to a user friendly format such as PDF
INSTALL SETTINGS MENU
CTD IntelliSet_2008_0219
ACME TRUCKING
(1 OF 3)
ACME EXPRESS
BACK
EXIT
INSTALL SETTINGS IN PROCESS
DO NOT REMOVE USB
INSTALL SETTINGS COMPLETE
SYSTEM WILL NOW RESET
33%
DO NOT REMOVE USB
INSTALL SETTINGS MENU
INSTALL SETTINGS MENU
Summary of Contents for Transicold X4 7300
Page 21: ...62 11637 1 6 1 3 SAFETY DECALS ...
Page 22: ...1 7 62 11637 62 03958 ...
Page 23: ...62 11637 1 8 ...
Page 24: ...1 9 62 11637 ...
Page 119: ...62 11637 SECTION 6 MESSAGECENTER PARAGRAPH NUMBER Page 6 1 MESSAGECENTER MESSAGES 6 1 ...
Page 278: ......