5–27
62-11637
SET DATE AND TIME
Indicates to the main microprocessor the current date and time. Refer to
for instructions on entering the date and time.
NOTE
Date and Time may also be configured under “Unit Identification”.
SATELLITE COMM
(This Configuration is an op-
tion, it will not display if the
option is not installed.)
OTHER
QUALCOMM
OTHER = The microprocessor is set for communica-
tion from Qualcomm T2 (Trailer Tracs 2) or any other
supplier.
QUALCOMM =- The microprocessor is set for com-
munication from Qualcomm Trailer Tracs.
RAIL SETTINGS
UNIT OPERATION
STANDARD
RAIL
RAIL = The system is set to control Rail refrigeration
operation. When this Configuration is set to “RAIL”
the following “VEHICLE ID”, “RAIL SHUTDOWN
OVERRIDE” and “RAIL OVERRIDE RESTARTS”
Sub-Configurations will be available.
• VEHICLE ID
ASSET
TRAILER
CAR
This Configuration modifies the prefix wording used
for display of the customer assigned ID number en-
tered in the “TRAILER ID” Configuration. For exam-
ple, if the customer assigned ID number entered is
12345:
ASSET = will display “ASSET # 12345”
TRAILER = will display “TRAILER # 12345”
CAR = will display “CAR # 12345”
• RAIL SHUTDOWN OVER-
RIDE
NO
YES
NO = When the A00030 - “FAILED TO RUN MIN
TIME” or A00031 - “FAILED TO START - AUTO”
alarm is activated, the system will not override the
alarm(s) and the unit will not restart until the alarms
are cleared manually.
YES = When either an A00030 - “FAILED TO RUN
MIN TIME” or A00031 - “FAILED TO START - AUTO
alarm is activated, the unit will automatically override
and clear the alarm(s) and attempt a restart after 4
hours. When this Configuration is set to “YES” the
following “RAIL OVERRIDE RESTARTS” Sub-Con-
figurations will be available.
• RAIL OVERRIDE RE-
STARTS
1-20
3
With the default setting the system is allowed to
override and clear the A00030 - “FAILED TO RUN
MIN TIME” or A00031 - “FAILED TO START - AUTO
alarm(s) three consecutive times before the override
is locked out and no further restart attempts will be
allowed until the alarm(s) are cleared manually.
The number of restart attempts allowed before the
override is locked out may be changed by entering
the desired number in this Sub-Configuration. Set-
ting this number too high may result in a discharged
or damaged battery if the unit never actually starts or
fails to run long enough to charge the battery prior to
shutting down again.
Table 5–1 Configuration Settings
Configuration
Selections
Description
Summary of Contents for Transicold X4 7300
Page 21: ...62 11637 1 6 1 3 SAFETY DECALS ...
Page 22: ...1 7 62 11637 62 03958 ...
Page 23: ...62 11637 1 8 ...
Page 24: ...1 9 62 11637 ...
Page 119: ...62 11637 SECTION 6 MESSAGECENTER PARAGRAPH NUMBER Page 6 1 MESSAGECENTER MESSAGES 6 1 ...
Page 278: ......