62-11637
6–2
DOOR OPEN
A refrigerated compartment door is open.
DOOR OPEN
−
LOW SPEED
A refrigerated compartment door is open forcing the unit to run in low
speed.
ENTERING SERVICE MODE
The initial message for Service Mode.
ERROR: ENG HRS > SWITCH ON
HRS
When setting up a replacement microprocessor, incorrect hours have
been entered
ERROR: HI SP HRS > TOTAL ENG
HRS
EVAC / CHARGE MODE
The unit is in Service Mode, and the refrigeration system is ready to be
evacuated then charged with refrigerant. Refer to Section 5.2.5
EXITING PRETRIP MODE
Pretrip has been aborted either by user or by a pretrip alarm.
EXITING SERVICE MODE
Service Mode has been turned off and unit is returning to normal opera-
tion.
INACTIVE ALARMS IN MEMORY
There are inactive alarms in the microprocessor alarm list which have not
yet been cleared.
INTELLI
−
SLEEP MODE
The IntelliSleep IntelliSet is active. This message alternates with
“CHANGE INTELLISET TO EXIT” at 5 second interval whether unit is
running or not.
KEYPAD (display mounted keys)
LOCKED
−
BATTERY TOO LOW
Once the battery voltage goes below 7.0 Volts for 10 seconds, all of the
keys on the display will be locked.
LOSS OF COMMUNICATIONS
There is a loss of communications between the display module or other
module(s). If a specific module is involved, the name of the module will
also be indicated.
MAX SETPOINT HAS BEEN
REACHED
Maximum setpoint allowed by configuration settings has been reached.
MICRO WILL RESET & RESTART
NOW
The microprocessor program software has just been changed, or a new
configuration has been programmed into the microprocessor. The micro-
processor will turn itself off then on again (similar to a computer reboot)
in order for the changes to be effective.
MIN SETPOINT HAS BEEN REACHED Minimum setpoint allowed by configuration settings has been reached.
MODIFIED
This message will appear in the MessageCenter along with the current
IntelliSet indicating that the IntelliSet is active and one or more of its set-
tings have been modified.
NO ACTIVE ALARMS
There are no active alarms in the microprocessor Alarm List.
NO INACTIVE ALARMS
There are no inactive alarms in the Alarm List
PC MODE
The START/RUN
−
OFF switch is in the OFF position, the engine is not
running in order to enter PC Mode.
PM DUE
Preventative Maintenance is now due on the unit. Information on what
meter(s) has timed out and the reset feature is provided under Technician
Hour Meters. Refer to
PRETRIP FAIL & COMPLETED
The Pretrip test is completed, and some of the Pretrip tests did not pass.
Check the Alarm List for Pretrip alarms.
PRETRIP FAIL IN TEST XX
Some of the Pretrip tests did not pass and the Pretrip was not completed.
Check the Alarm List for Pretrip alarms.
Table 6–1 MessageCenter Messages
Message
Description