6
6
6-26
6-26
Installation > Installation Procedure > Connecting to the Upstream Connection Machine
Installation > Installation Procedure > Connecting to the Upstream Connection Machine
9) After removing the interface cables from the wire saddles on the
rear of the host machine, release the two hooks to remove the
interface cover.
x3
x2
F-6-66
F-6-66
10) Connect the interface cable to the host machine.
x1
F-6-67
F-6-67
Caution:
When connecting the interface cable,
be sure to turn off the host machine
and disconnect its power cable from
the outlet. If you do not do so, electric
shock can result.
11) Attach the interface cover removed in step 9) to the host machine by
engaging its two hooks as putting the cables through the grooves of the
cover, and then secure the interface cables to the wire saddles.
x2
x3
F-6-68
F-6-68
Caution:
When attaching the interface cover,
be careful not to pinch or damage the
cable harness.
12) Attach the wire saddle to the upper rear cover.
F-6-69
F-6-69