Connecting to Paper Folding Unit
1) Using four screws, attach two ground plates and two latch catches (front and rear) on the
left side of the paper folding unit together.
x4
F-6-52
F-6-52
MEMO:
The ground plate and latch
catch have three screw
holes each. Use two screw
holes according to the
mounting position on the
paper folding unit.
A pair of the ground plates
and the latch catches are
identical to each other.
•
•
2) Attach the positioning pin using two screws.
x2
F-6-53
F-6-53
■