Removing the Static Eliminators (Swing Guide Unit)
1) Remove the grate-
shaped upper guide.
2) Lower the swing guide.
F-4-100
3)Remove the 6 screws and then remove the swing guide upper
cover.
x6
F-4-101
CAUTION:
When the swing guide upper cover is reassembled, put
the arms of swing guide in the link holder.
F-4-102
4) Remove each 2 screws and detach the static eliminators front and
left.
x2