COPYRIGHT© 2001 CANON INC.
2000 2000 2000 2000
CANON SADDLE FINISHER K3/K4 REV.0 MAR. 2001
5-76
CHAPTER 5 TROUBLESHOOTING
3.1.6 E514 (stack delivery motor M7 fault)
-
1) Does the stack delivery motor rotate in keeping with delivery of
stacks?
YES: Go to step 2.
NO:
Go to step 4.
Wiring
2) Is the wiring between the finisher controller PCB and the sensor
normal?
NO:
Correct the wring.
Sensor power supply, Stack delivery motor clock sensor (PI10)
3) Measure the voltage between J105B-8 (+) and J105B-7 (-) on the
finisher controller PCB. Is it 5 VDC?
NO:
Replace the finisher controller PCB.
YES: Replace the sensor.
Power supply, Finisher controller PCB
4) Is the voltage at J101-1 (+) on the finisher controller PCB 24 V?
NO:
Check the switching regulator and the fuse PCB.
YES: Replace the finisher controller PCB.