4) Remove the two screws [3], and detach
the magnet catch plate [4]; then, remove
the screw [5], and detach the latch fix-
ing plate [6].
F03-302-02
5) Free the hook (front, [7]).
6) Disconnect the folder from the copier.
F03-302-03
3.2.2 Removing the Folder (upper)
1) Disconnect the folder from the copier.
2) Disconnect the three connectors [1]
connected to the finisher unit, and free
the harness from the holder [2].
F03-302-04
[4]
[6]
[3]
[5]
[7]