COPYRIGHT© 2001 CANON INC.
2000 2000 2000 2000
CANON SADDLE FINISHER K3/K4 REV.0 MAR. 2001
3-58
CHAPTER 3 MECHANICAL SYSTEMS
2.1.4 Mounting the Positioning
Plate Unit
1) Remove the PCB cover.
2) Remove the four screws [1], and discon-
nect the 17 connectors [2]; then, detach
the saddle stitcher controller PCB [3].
F03-201-34
3) Disconnect the two connectors [4], and
remove the two screws [5].
4) While shifting the unit [6] to the left/
right, detach it.
F03-201-35
[3]
[1]
[1]
[1]
[2]
[1]
[6]
[4]
[5]