3-79
CHAPTER 3 MECHANICAL SYSTEMS
3.4.2 Positioning the Coupling for
the Horizontal Path Drive
1) Separate the folder from h copier.
2) Loosen the two screws [1].
3) Slide in and out the folder unit [2] two
to three times so that the coupling [3] of
the horizontal path drive will be cor-
rectly positioned.
F03-304-03
4) Push in the folder unit, and tighten the
two screws loosened in step 2).
[1]
[2]
[3]