COPYRIGHT© 2001 CANON INC.
2000 2000 2000 2000
CANON SADDLE FINISHER K3/K4 REV.0 MAR. 2001
3-74
CHAPTER 3 MECHANICAL SYSTEMS
3.3.3 Adjusting the Pressure of the
Folding Roller
1) Remove the folder front cover and the
rear cover.
2) Remove the four screws [1], and detach
the inside cover (front; [2]).
F03-303-07
[1]
[2]
[1]
[1]
[2]
[1]