CANON SADDLE FINISHER K3/K4 REV.0 MAR. 2001
2-94
CHAPTER 2 OPERATION OVERVIEW
11 MODULE ISOLATION
11.1.1 Overview
If an error occurs in one of the modules, the finisher system enables the module con-
cerned to be isolated and another to be operated. If an error related to a certain module oc-
curs, the module concerned can be isolated by turning off the corresponding DIPswitch bit
on the switch PCB provided in the saddle stitcher. The table below shows the units where
the module isolation applies and the conditions when the module is isolated.
Units where module isolation applies
SW971 No.
SW971-1
-2
-3
-4
-5
-6
Unit
Punch Unit
Tray A
Inserter
Folder
Saddle stitcher unit
Not used
Condition when cut off
Power flow is stopped. Connection is detected, but operation is
prohibited. The position of the punch unit must be initialized
by the user.
Power flow is stopped. Position of tray A must be adjusted by
user. Tray A is used as a fixed tray.
Power flow is stopped. Connection is detected, but operation is
prohibited.
Power flow is stopped. Connection is detected, but operation is
prohibited.
Power flow is stopped. Connection is detected, but operation is
prohibited.
T02-1101-01
This table shows the errors for which the module can be isolated in each unit.
Unit
Punch unit
Tray A
Inserter
Folder
Saddle stitcher
Error
E590, E593, E594
E540
E515
E518
E5F0, E5F1, E5F2, E5F3, E5F4, E5F5, E5F6, E5F7, E5F8, E5F9
T02-1101-02