COPYRIGHT© 2001 CANON INC.
2000 2000 2000 2000
CANON SADDLE FINISHER K3/K4 REV.0 MAR. 2001
3-24
CHAPTER 3 MECHANICAL SYSTEMS
4) Loosen the three screws [4] of the sole-
noid unit.
F03-103-15
5) Cause the solenoid to become attracted.
(F03-103-16-A)
6) With the solenoid attracted, hook your
finger on the solenoid shaft [5], and pull
the solenoid body. (F03-103-16-B)
7) When the support member of the lever
unit is pulled as far as it butts against
the stopper, tighten the screw [4].
F03-103-16
1.3.7 Position of Tray B at Power-On
The tray B [1] must not be above the tray
B paper sensor [2] at power on. If it is, an
error will be issued when the position of the
tray B is checked.
F03-103-17
[4]
[4]
A
[5]
B
[1]
[2]
[2]