P
age
41
- Manual
FA01894-EN
- 09/2022 - © C
AME S.p.A. - The contents of this manual may be changed at any time and without notice. - T
ranslation of the o
riginal instructions
Signal maintenance
Set the colour of the fl ash on enabled BUS devices (fl ashing beacons and selectors) when maintenance is necessary. With the
function activated, these devices will signal that maintenance needs to be carried out at the start of each manoeuvre.
Confi gure maintenance and set the number of manoeuvres. See function [Confi gure maintenance].
The function only appears if there is a BUS fl ashing beacon or a BUS selector connected.
Confi guration>
BUS Devices>
BUS device lights
Signal maintenance
Deactivated (Default)
White
Yellow
Orange
Red
Purple
Blue
Light blue
Green
Command 2-7
Associate a command to the connected device on 2-7.
Confi guration>
Command inputs
Command 2-7
Step-by-step (Default) - The fi rst command is to open and
the second to close.
Sequential - The fi rst command is to open, the second to
STOP, the third to close and the fourth to STOP.
Lock
Associate the electric lock/electromagnet release with a command.
Confi guration>
Functions
Lock
Deactivated (Default)
From closed
From open
From open and closed
Continue
Electromagnet 24 V
The electromagnet activates when the motor is
stationary and deactivates during a manoeuvre.
Closing thrust
When the leaves reach the closing limit-switch, the operator thrusts them towards the strike plate for a second.
Confi guration>
Functions
Closing thrust
Deactivated (Default)
Minimum
Medium
Maximum