P
age
31
- Manual
FA01894-EN
- 09/2022 - © C
AME S.p.A. - The contents of this manual may be changed at any time and without notice. - T
ranslation of the o
riginal instructions
List of functions
Number of motors
Set the number of motors that control the gate.
Confi guration>
Motor settings
Number of motors
M1+M2 (Default)
M2
Opening direction
Set the gate opening direction.
By selecting an opening direction for M2, M1 is automatically set to the opposite direction.
Confi guration>
Motor settings
M2 opening direction
Anticlockwise (Default)
Leaf M2 opens anticlockwise, leaf M1 opens clockwise.
Clockwise
Leaf M2 opens clockwise, leaf M1 opens anticlockwise.
Type of motor arm
Set the type of motor arm installed on M1 and M2.
Confi guration>
Motor settings
Type of motor arm
Standard (Default)
140° transmiss. kit (001A4370)
180° transmiss. kit (801XA-0040)
Motor test
Check the gate leaves open in the right direction.
With the function active, the > button opens/closes the gate leaf connected to M2, and the < button opens/closes the gate
leaf connected to M1. The movement continues as long as the button is pressed or until the end-of-travel limit switch is
reached. When the button is released, the movement stops.
The leaves will move at reduced speed.
Confi guration>
Motor settings
Motor test
The > button opens and closes gate leaf M2
The < button opens and closes gate leaf M1
Travel calibration
Start the travel self-learning.
Confi guration>
Motor settings
Travel calibration
Gate-leaf length
Set the length of leaves M1 and M2.
Confi guration>
Motor settings
Gate-leaf length
Maximum (Default)
0.5 to 4 m (increments of 0.5 m)