Maximum capacity of contacts
The total power of the outputs listed below must not exceed the maximum output power [Accessories]
Device
Output
Power supply (V)
Maximum power
(W)
Accessories
10 - 11
24 AC/DC
40
Additional light
10 - E3
24 AC/DC
20
Flashing beacon
10 - E
24 AC/DC
20
Operator status warning light
10 - 5
24 AC/DC
3
The output delivers 24 V DC (10+, 11-) when the batteries start operating, if they are installed.
Device
Output
Power supply (V)
Power (W)
Auxiliary contact
B1 - B2
-
24 (24V AC/DC)
BUS CXN
BUS
15 DC
15
Do not connect anything other than CAME BUS accessories.
FROG X gearmotors (801MI-0020)
Connecting gearmotor pair
M1 =Gearmotor delayed while opening
M2 =Gearmotor delayed while closing
M1
M2
M2
M1
M1
M2