Safety devices
During programming, confi gure the type of action that must be performed by the device connected to the input.
Connect the safety devices to the CX and/or CY and/or CZ and/or CK inputs.
If used, the contacts C1 CX CY CZ CK must be confi gured during programming.
For systems with multiple pairs of photocells, please see the manual for the relevant accessory.
DELTA photocells
Standard connection
DELTA photocells
Connection with safety test
See [Safety devices test] function.
10 TS 2 CX CY CZ CK
10 11 E E3 5
+
10
-
11 NO C NC
+
10
-
11
RX
TX
10 TS 2 CX CY CZ CK
10 11 E E3 5
+
10
-
11 NO C NC
+
10
-
11
RX
TX
DIR / DELTA-S photocells
Standard connection
DIR / DELTA-S photocells
Connection with safety test
See [Safety devices test] function.
10 TS 2 CX CY CZ CK
10 11 E E3 5
+
10
-
2 TX C NC
+
TX
-
2
RX
TX
10 TS 2 CX CY CZ CK
10 11 E E3 5
+
10
-
2 TX C NC
+
TX
-
2
RX
TX