Travel AST control
Adjust the obstruction detection sensitivity during the gate travel in percentage terms.
Confi guration>
Gate travel settings
Travel AST control
Deactivated (Default)
Maximum thrust and low obstruction sensitivity.
Minimum
Average
Maximum*
(*)
Minimum thrust and high obstruction
sensitivity.
Customised
Customised closing
Customised opening
The personalised values to be used are expressed as a
percentage:
- from 10% (minimum thrust and high obstruction
sensitivity)
- to 100% (maximum thrust and low obstruction sensitivity)
Adjusting the partial opening
For single-leaf gates, it determines the partial opening percentage of the leaf with respect to the total travel.
For two-leaf gates, it determines the partial opening percentage of the M2 leaf with respect to the total travel.
100% = Pedestrian opening
Confi guration>
Gate travel settings
Part. open point
10% to 100% (Default 100%)
Opening approach space
Set the percentage of the total travel to be used for the M1 and M2 opening approach.
If the value set for M1 is diff erent to the value set for M2, only the value for M2 is shown here.
Confi guration
Gate travel settings
Op. approach point
0.5% to 25.0% (Default 8.0%)
Closing approach space
Set the percentage of the total travel to be used for the M1 and M2 closing approach.
If the value set for M1 is diff erent to the value set for M2, only the value for M2 is shown here.
Confi guration>
Gate travel settings
Cl. approach point
0.5% to 25.0% (Default 8.0%)
Opening slowdown point
Set the percentage of the total travel to be used for the M1 and M2 opening slowdown.
If the value set for M1 is diff erent to the value set for M2, only the value for M2 is shown here.
Confi guration>
Gate travel settings
Opening slowdown point
Deactivated (Default)
1% to 50%