Pre-fl ashing time
Adjust the time for which the beacon is activated before each manoeuvre.
Confi guration>
Manage lights
Pre-fl ashing time
Deactivated (Default)
1 to 10 seconds
CRP address
Assign a unique identifi cation code (CRP address) to the control board.
The function is used where there are multiple operators connected to the same communication BUS using the
CRP protocol.
Confi guration>
RSE communication
CRP address
1 to 254 (Default 1)
RSE speed
Set the communication speed of the remote connection system.
Confi guration>
RSE communication
RSE speed
4800 bps
9600 bps
14400 bps
19200 bps
38400 bps (Default)
57600 bps
115200 bps
Save data
Save user data, timings and confi gurations to the memory device (memory roll).
The function is displayed only when a memory roll card is inserted into the control board.
Confi guration>
External memory
Save data
Read data
Upload user data, timings and confi gurations to the memory device (memory roll).
The function is displayed only when a memory roll card is inserted into the control board.
Confi guration>
External memory
Read data
Parameter reset
Restore the factory confi gurations except for: [users], [timers], [no. motors], [CRP address], [RSE speed], [password],
[language], [time format] and the settings related to calibration.
Confi guration
Parameter reset
Confi rm? NO
Confi rm? YES
Guided procedure (Wizard)
You can use the system confi guration wizard.
Confi guration
Guided procedure (Wizard)