P
age
35
- Manual
FA01894-EN
- 09/2022 - © C
AME S.p.A. - The contents of this manual may be changed at any time and without notice. - T
ranslation of the o
riginal instructions
Impact test
Activate/deactivate test mode for impact tests. With the function on, the operator does not signal errors connected to obstacle
detection after more than one consecutive impact.
Test mode is deactivated automatically after 1 hour.
With the function on, the display shows the
icon.
Confi guration>
Gate travel settings
Impact test
Activate test mode
Deactivate test mode
Confi gure travel M1
Modify certain parameters previously described for motor M1 only (where diff erent from M2).
The function only appears with M1+M2 selected under [Number of motors].
Confi guration>
Gate travel settings>
Confi gure M1
Opening speed
Closing speed
Opening approach space
Closing approach space
Opening slowdown point
Closing slowdown point
Opening slowdown speed
Closing slowdown speed
See the specifi c parameters for each function.
Confi gure travel M2
Modify certain parameters previously described for motor M2 only (where diff erent from M1).
The function only appears with M1+M2 selected under [Number of motors].
Confi guration>
Gate travel settings>
Confi gure M2
Opening speed
Closing speed
Opening approach space
Closing approach space
Opening slowdown point
Closing slowdown point
Opening slowdown speed
Closing slowdown speed
See the specifi c parameters for each function.
Total stop
Activate or deactivate input 2-1. If it is activated, the input is used as a normally closed contact.
With the input open, this function excludes all commands, including any automatic closing.
Confi guration>
Wired safety devices
Total stop
Deactivated (Default)
On