GENERAL PRECAUTIONS FOR INSTALLERS
Important safety instructions.
Please follow all of these instructions. Improper installation may cause
serious bodily harm.
Before continuing, please also read the general precautions for users.
Only use this product for its intended purpose. Any other use is hazardous. • The
manufacturer cannot be held liable for any damage caused by improper, unreasonable
or erroneous use. • This product has been designed to be assembled to partly
completed machinery and/or equipment so as to build machinery as regulated by
the Machinery Directive 2006/42/EC. • The fi nal installation must comply with the
Machinery Directive (2006/42/EC) and the European reference standards in force. •
The manufacturer declines any liability for using non-original products, which would
also void the warranty. • All operations indicated in this manual must be carried
out exclusively by skilled and qualifi ed personnel and in full compliance with the
regulations in force. • The device must be installed, wired, connected and tested
according to good professional practice, in compliance with the standards and laws
in force. • Make sure the mains power supply is disconnected during all installation
procedures. • All the components (e.g. actuators, photocells and sensitive edges)
needed for the fi nal installation to comply with the Machinery Directive (2006/42/
EC) and with the reference harmonised technical standards are specifi ed in the
general CAME product catalogue or on the website www.came.com. • Check that
the temperature ranges given are suitable for the installation site. • Make sure that
no direct jets of water can wet the product at the installation site (sprinklers, water
cleaners, etc.). • Make sure you have set up a suitable dual-pole cut-off device along
the power supply that is compliant with the installation rules. It should completely
cut off the power supply according to category III surcharge conditions. • Demarcate
the entire site properly to prevent unauthorised personnel from entering, especially
minors. • Use suitable protection to prevent any mechanical hazards due to persons
loitering within the operating range of the operator. • The electrical cables must
pass through special pipes, ducts and cable glands in order to guarantee adequate
protection against mechanical damage. • The electrical cables must not touch any
parts that may overheat during use (such as the motor and transformer). • Before
installation, check that the guided part is in good mechanical condition, and that it
opens and closes correctly.