P
age
47
- Manual
FA01894-EN
- 09/2022 - © C
AME S.p.A. - The contents of this manual may be changed at any time and without notice. - T
ranslation of the o
riginal instructions
FW version
Display the fi rmware version number and the GUI installed.
Information
FW version
Use the < > arrows to show:
FW MC.x.x.xx (motor board fi rmware version)
FW UI.x.x.xx (display board fi rmware version)
GUI x.x (graphics)
BUS device status
Show the status of all devices that can be connected to the BUS and managed by the fi rmware in use.
Key
<n> is the device number.
Information
BUS device status
BUS photocells <n>
<n> from 1 to 8
The status shown may be:
OK
Not communicating
Safety device active
BUS address confl ict
BUS selector <n>
<n> from 1 to 7
The status shown may be:
OK
Not communicating
BUS address confl ict
BUS fl ashing beacon <n>
<n> from 1 to 2
The status shown may be:
OK
Not communicating
BUS address confl ict
I/O module BUS <n>
<n> from 1 to 2
The status shown may be:
ok
not communicating
BUS address confl ict
Manoeuvre counter
View the number of total or partial operator manoeuvres (after maintenance).
The number of manoeuvres is the number shown multiplied by 100.
Information
Manoeuvre counter
Total manoeuvres - Manoeuvres performed since the
operator was installed.
Partial manoeuvres - Manoeuvres carried out after the last
maintenance.