P
age
36
- Manual
FA01894-EN
- 09/2022 - © C
AME S.p.A. - The contents of this manual may be changed at any time and without notice. - T
ranslation of the o
riginal instructions
CX input , CY input , CZ input , CK input
Associate a function with the input CX CY CZ CK
Confi guration>
Wired safety devices
CX input
CY input
CZ input
CK input
Deactivated (Default)
C1 = Reopen while closing (photocells)
C2 = Reclose while opening (photocells)
C3 = Partial stop Only with [Automatic close] activated.
C4 = Obstacle standby (photocells)
C7 = Reopen while closing (sensitive edges)
C8 = Reclose while opening (sensitive edges)
C13 = Reopen while closing, with immediate closure once
the obstruction has been removed, even if the gate is not
in motion
r7 = Reopen while closing (sensitive edge with 8K2
resistor)
r8 = Reclose while opening (sensitive edge with 8K2
resistor)
r7 (two sensitive edges) = Reopen while closing (pair of
sensitive edges with 8K2 resistor)
r8 (two sensitive edges) = Reclose while opening (pair of
sensitive edges with 8K2 resistor)
Safety devices test
Check that the photocells connected to the selected inputs are operating correctly, after each opening and closing command.
Run the test by connecting the photocells to the TS terminal [see paragraph on Safety devices].
Confi guration>
Wired safety devices
Safety devices test
Deactivated (Default)
CX _ _ _
_ CY _ _
CX CY _ _
_ _ CZ _
CX _ CZ _
_ CY CZ _
CX CY CZ _
_ _ _ CK
CX _ _ CK
_ CY _ CK
CX CY _ CK
_ _ CZ CK
CX _ CZ CK
_ CY CZ CK
CX CY CZ CK