background image

EN

Page 8 / 32

VAL_SC Rev24 - Operating Instructions

1.4. Warranty

For the product warranty refer to the general terms and 

conditions of sale. 

i

  The warranty covers only the replacement and 

the repair of the defective parts of the goods 

(recognized by the manufacturer).

The Warranty will not be considered in the following 

cases:

-  Whenever the use of the device does not conform 

to the instructions and information described in this 

manual.

-  

In case of changes or variations made without 

authorization of the manufacturer.

-  In case of technical interventions executed by a non-

authorized personnel.

- In case of failing to carry out adequate maintenance.

1.5. Technical assistance

Any further information about the documentation, 

technical assistance and spare parts, shall be 

requested from: Calpeda S.p.A. (paragraph 1.2).

2.  TECHNICAL DESCRIPTION

Vertical column sump pumps, with motor in dry 

installation and with pump body submerged in the 

liquid handled (without suction line or foot valve).

Impeller

 

- VAL:  free-low  impeller  (vortex  or 

recessed impeller).

 

- SC:  open impeller.

Connection

 -  

VAL 30, SC 30, SC 50: threaded port 

ISO 228 (BS 2779).

 

- VAL 65: lange  with  plain  face  oval   

 

threaded counter-lange UNI 2245, PN 2,5.

2.1. Intended use

-  

For draining a basin or a sump with domestic or 

industrial sewage.

-  For slightly dirty waste water, for liquids which are 

non-aggessive for the pump materials.

- Maximum size of solids:

 

VAL 30

 = 25 mm; 

VAL 65

 = 50 mm;

 

SC 30

 = 3 mm; 

SC 50

 = 6 mm.

Liquid temperature up to 40 °C.

2.2. Improper use

The device is designed and built only for the purpose 

described in paragraph 2.1.

  Improper use of the device is forbidden, as is 

use under conditions other than those indicated 

in these instructions.

Improper use of the product reduces the safety and 

the  eficiency  of  the  device,  Calpeda  shall  not  be 

responsible for failure or accident due to improper use.

2.3. Marking

The following picture is a copy of the name-plate (see 

Pic.1) that is on the external case of the pump.

1 Pump type

2 Delivery

3 Head

4 Rated power

5 Tension nominale

6 Nom. motor current

7 Notes

8 Fréquence

9 Operation Duty

10 Insulation class

11 Weight

12 Power factor

13 Rotation speed rpm

14 Protection

15 Serial number

16 Certiications

Example plate pump

XXXXXXX

Q min/max 

X/X

 m

3

/h

XXXXXXX

H max/min 

X/X

 m

IP 

XX

XXXX

/min

220∆/380Y V3~50Hz

cosø 

X

X/X

 A

XXXXXXXX

S1   l.cl. 

X

   

X

 kg

X

 kW   (

X

Hp)    S.F.

1
2
3
4

5
6
7

8

9 10

16

15

14

13
12
11

Montorso (VI) Italy  IT 00142630243

Made in Italy

3.  TECHNICAL FEATURES

3.1. Technical data

Dimensions and weight (see technical catalogue).

Nominal speed 2900/3450 rpm

Protection IP54 (IP 55 Special construction)

Supply voltage / Frequency:

- up to 240V 1~ 50/60 Hz

- up to 480V 3~ 50/60 Hz 

Check that the mains frequency  and voltage 

correspond to the electrical characteristics shown on 

the indicator plate.

The electric data marked on the label are referred to 

the nominal power of the motor.

Sound pressure:  ≤ 70 dB (A);

Max. starts per hour: 30 at regular intervals.
Maximum suction pressure: PN (Pa) - Hmax (Pa).

3.2. Operating conditions

Installation in well ventilated location protected from 

the weather, with a maximum ambient temperature of 

40 °C.

4.  SAFETY

4.1. General provisions

  

Before using the product it is necessary to 

know  all the safety indications.

Carefully read all operating instructions and the 

indications  deined  for  the  different  steps:  from 

transportation to disposal.

The specialized technicians must carefully comply 

with all applicable standards and laws, including local 

regulations of the country where the pump is sold.

The device has been built in conformity with the current 

safety laws. The improper use could damage people, 

animals and objects.

The manufacturer declines any liability in the event of 

damage due to improper use or use under conditions 

other than those indicated on the name-plate and in 

these instructions.

i

  Follow the routine maintenance schedules and 

the promptly replace damaged parts, this will 

allows the device to work in the best conditions.

Use only original spare parts provided from Calpeda 

S.p.A or from an authorized distributor.

  Don’t remove or change the labels placed on 

the device. 

Do not start the device in case of defects or damaged 

parts.

  Maintenance operations, requiring full or partial 

disassembly of the device, must be done only 

after disconnection from the supply.

4.2. Safety devices

The device has an external case that prevents any 

contact with internal parts.

4.3. Residual risks

The appliance, designed for use, when used in-line 

with the design and safety rules, doesn’t have residual 

risks.

4.4. Information and Safety signals

For this kind of product there will not be any signals 

on the product.

4.5. Individual protection devices

During installation, starting and maintenance it is 

suggested to the authorized operators to consider 

 

Summary of Contents for VAL

Page 1: ...mps sump pumps Vertikale Tauchpumpen Pompes immerg es verticales VAL SC ISTRUZIONI ORIGINALI PER L USO Pagina 2 Italiano OPERATING INSTRUCTIONS Page 7 English BETRIEBSANLEITUNG Seite 12 Deutsch INSTRU...

Page 2: ...rimenti sono causa di danneggiamenti all apparecchio o compromettono la sicurezza del personale Informazioni ed avvertenze di carattere elettrico il cui mancato rispetto pu danneggiare l apparecchio o...

Page 3: ...8 9 10 16 15 14 13 12 11 Montorso VI Italy IT 00142630243 Made in Italy 3 CARATTERISTICHE TECNICHE 3 1 Dati tecnici Dimensioni di ingombro e pesi vedi catalogo Velocit nominale 2900 3450 rpm Protezio...

Page 4: ...vede che sul fondo del pozzetto possa formarsi della melma di deposito prevedere opportuno appoggio che mantenga l elettropompa sollevata Prevedere ancoraggi adatti alla lunghezza e peso della elettro...

Page 5: ...tenzione dell apparecchio contattare CALPEDA S p A 8 1 Manutenzione ordinaria OFF Nelle condizioni d impiego normali la pompa non richiede manutenzioni Prima di ogni intervento di manutenzione toglier...

Page 6: ...el dispositivo di protezione del motore d Fusibili bruciati o difettosi e Albero bloccato f Motore in avaria a Veriicare che la frequenza e la tensione di rete sia idonea b Collegare correttamente il...

Page 7: ...t be observed otherwise there is a risk that the machine could damage or compromise personnel safety The failure to observe electrical information and warnings could damage the machine or compromise p...

Page 8: ...220 380Y V3 50Hz cos X X X A XXXXXXXX S1 l cl X X kg X kW XHp S F 1 2 3 4 5 6 7 8 9 10 16 15 14 13 12 11 Montorso VI Italy IT 00142630243 Made in Italy 3 TECHNICAL FEATURES 3 1 Technical data Dimensio...

Page 9: ...ided to keep the pump raised Secure pump and delivery pipe to suitable rests 6 5 Electrical connection OFF Electrical connection must be carried out only by a qualiied electrician in accordance with l...

Page 10: ...the device could not accidentally operate The pump may have been immersed in hazardous substances or products emanating toxic gases or may be located in an environment which is toxic due to other reas...

Page 11: ...e overload protective device cuts in 1d Blown or defective fuses 1e Shaft blocked 1f Motor failed 1a Check that the mains frequency and voltage are suitable 1b Connect the power supply cable correctly...

Page 12: ...rechenden Bedeutungen im Folgenden aufgelistet Informationen und Hinweise welche zu beachten sind um Besch digungen an dem Ger t oder M ngel an der Sicherheit des Personals zu vermeiden Informationen...

Page 13: ...14 13 12 11 Montorso VI Italy IT 00142630243 Made in Italy 3 TECHNISCHE MERKMALE 3 1 Technische Daten Abmessungen und Gewicht siehe Katalog Nenndrehzahl 2900 3450 rpm Schutzklasse IP 54 IP 55 Sondera...

Page 14: ...alliert werden um oberhalb der Ablagerungen frei laufen zu k nnen Die Pumpe und die F rderleitung sind je nach L nge und Gewicht mit geeigneten Mitteln zu befestigen 6 5 Elektrischer Anschlu OFF Der e...

Page 15: ...Spannung gesetzt werden darf Die Pumpe k nnte in gesundheitsgef hrdenden bzw giftige Gase ausstr menden Fluiden eingesetzt worden sein Ebenso k nnen sich aus sonstigen Gr nden in dem Aufstellungsort d...

Page 16: ...cherungen defekt oder ausgel st e Welle blockiert f Fallsalle zuvorgenannten M glichkeiten berpr ft wurden liegt evtl ein defekt des Motors vor a berpr fen Sie ob die Netzfrequenz und spannung geeigne...

Page 17: ...compromettent la s curit du personnel Informations et avertissements de caract re lectrique qui s ils ne sont pas respect s peuvent causer des dommages l appareil et compromettre la s curit du person...

Page 18: ...RISTIQUES TECHNIQUES 3 1 Donn es techniques Dimensions d encombrement et poids voir catalogue technique Vitesse nominale 2900 3450 rpm Protection IP 54 IP 55 Construction sp ciale Tension d alimentat...

Page 19: ...ovoqu par eventuelles missions toxiques sur le lieu d installation Le diam tre int rieur du tube de refoulement ne peut tre inf rieur au diam tre de l oriice de la pompe Si des d p ts de vase sont sus...

Page 20: ...maintenance Les op rations de maintenance non d crites dans ce manuel doivent tre ex cut es uniquement par du personnel sp cialis envoy par CALPEDA S p A Pour toute autre renseignement technique conce...

Page 21: ...p ration Eviter le fonctionnement sec m me pour une courte dur e Suivre strictement les instructions d utilisation et si n cessaire contacter le revendeur ato PROBL MES CAUSES PROBABLES SOLUTIONS POSS...

Page 22: ...P A 1 Calpeda S p A 2 3 CE 8 3 1 6 5 6 5 1 1 i OFF ON 1 2 Calpeda S p A Via Roggia di Mezzo 39 36050 Montorso Vicentino Vicenza Italia www calpeda it 1 3 i 1 4 i 1 22 2 23 3 23 4 23 5 24 6 24 7 24 8...

Page 23: ...4 5 6 7 8 9 10 11 12 13 14 15 16 XXXXXXX Q min max X X m3 h XXXXXXX H max min X X m IP XX n XXXX min 220 380Y V3 50Hz cos X X X A XXXXXXXX S1 l cl X X kg X kW XHp S F 1 2 3 4 5 6 7 8 9 10 16 15 14 13...

Page 24: ...RU C 24 32 VAL_SC Rev24 5 5 1 25 6 6 1 6 2 3 2 6 3 i 6 4 0 6 0 6 p 6 5 OFF 07 RN F 12 3 TAB 1 I N 30 mA 3 D VALM SCM 50 220 240 7 7 1 7 2 OFF...

Page 25: ...RU VAL_SC Rev24 C 25 32 5 7 3 ON 6 5 8 i i Calpeda S p A Calpeda S p A 8 1 OFF rp n 8 2 OFF 73 00 64 24 70 18 78 00 64 00 52 00 14 24 14 00 28 04 28 00 28 20 64 00 8 3 IP55 OFF IP55 LOCTITE 510...

Page 26: ...12 13 16 13 20 14 00 14 24 14 29 28 00 28 04 28 08 28 20 50 00 52 00 52 04 54 00 54 04 54 08 56 00 64 00 64 08 64 20 64 24 70 00 70 18 70 20 73 00 76 00 76 04 76 54 78 00 81 00 82 00 82 04 82 08 88 00...

Page 27: ...rical diagram for single phase pumps VALM SCM with loat switch Schaltbilt f r einphasen Wechselstrompumpen VALM SCM mit Schwimmerschalter Sch ma lectrique pompes monophas es VALM SCM avec interrupteur...

Page 28: ...e Dessin pour d montage et montage Dibujo para desmontaje y montaje Ritning f r demontering och montering Onderdelentekening 88 00 82 00 82 04 81 00 92 00 73 00 70 00 70 18 56 00 54 04 90 00 76 00 94...

Page 29: ...lo smontaggio ed il rimontaggio Drawing for dismantling and assembly Zeichnung f r Demontage und Montage Dessin pour d montage et montage Dibujo para desmontaje y montaje Ritning f r demontering och...

Page 30: ...50 78 00 64 24 90 04 54 08 50 00 14 24 28 00 64 00 52 00 14 00 28 20 28 04 54 00 14 29 1 94 022 12 2 Disegno per lo smontaggio ed il rimontaggio Drawing for dismantling and assembly Zeichnung f r Dem...

Page 31: ...mm 2 Corrente nominale dell apparecchio Rated current of appliance Bemessungsstrom des Gerates Courant nominal de l appareil Corriente nominal del aparato Enhetens nominella str m Dimensiestroom van...

Page 32: ...e la Comisi n n 640 2009 DK OVERENSSTEMMELSESERKL RING Vi CALPEDA S p A erkl rer hermed at vore pumper VAL SC VALM SCM pumpe type og serie nummer vist p typeskiltet er fremstillet i overensstemmelse m...

Reviews: