background image

EN

VAL_SC Rev24 - Operating Instructions

Page 11 / 32

10.  SPARE PARTS

10.1. 

Spare-parts request

When ordering spare parts, please quote their 

designation, position number in the cross section 

drawing and rated data from the pump name plate 

(type, date and serial number).

The spare parts request shall be sent to CALPEDA 

S.p.A. by phone, fax, e-mail.

11.  ESIGNATION OF PARTS

Nr. Designation

12.00 

Casing cover

12.20 Screw

13.12 

Delivery side counterlange

13.16 Screw

13.20 Nut

14.00 

Pump casing

14.24 Screw

14.29 Washer

28.00 Impeller

28.04 

Impeller nut (or screw)

28.08 Washer

28.20 Key

50.00 

Lower bearing bush housing

52.00 

Bearing sleeve

52.04 

Grub screw

54.00 

Support column

54.04 

Grub screw

54.08 

Grub screw

56.00 Adapter

64.00 

Pump shaft

64.08 

Shaft sleeve

64.20 Key

64.24 

Shear pin

70.00 

Motor cover, pump side

70.18 Screw

70.20 Screw

73.00 

Pump side ball bearing

76.00 

Motor casing with winding

76.04 

Cable gland

76.54 

Terminal board, set

78.00 

Shaft with rotor packet

81.00 

Fan side ball bearing

82.00 

Motor end shield, fan side

82.04 

Compensating spring

82.08 Screw

88.00 

Motor fan

90.00 

Fan cover

90.04 Screw

94.00 Capacitor

94.04 

Capacitor collar

98.00 

Terminal box cover

98.04 Screw

98.08 Gasket

Changes reserved.

12.  TROUBLESHOOTING

OFF

 

    

WARNING

: Turn off the power supply before performing any operations.

 Do not allow the pump or motor to run  when dry even for a short period.

 Strictly follow the user instructions and if necessary contact an authorised service centre.

PROBLEM

PROBABLE CAUSES

POSSIBLE REMEDIES

1)
The motor does 
not start

1a) Unsuitable power supply
1b) Incorrect electrical connections 
1c)  Engine overload protective device cuts 

in.

1d) Blown or defective fuses
1e) Shaft blocked
1f) Motor failed

1a) Check that the mains frequency  and voltage are suitable.
1b)  Connect the power supply cable correctly. Check the setting of the 

thermal overload protection.

1c)  Check the power supply and make sure that the pump shaft is turning 

freely. Check the setting of the thermal overload protection.

1d) Replace the fuses, check points a) and  c)
1e) See “Blocked  pump” instruction booklet
1f) Repair  or replace the engine.

2) 
Pump blocked

2a) Prolonged periods of inactivity .
2b) Presence of solid bodies in the impeller
2c) Bearings or bearing sleeve siezed

2a) Unblock the pump by using a screw driver to turn the relevant notch 
on the back of the shaft.
2b) Remove any solid foreign bodies inside the impeller
2c) Replace the bearings or bearing sleeve. 

3) 
The pump 
functions  
but no water 
comes out 

3a)    

Insuficient immersion depth

3b) Possible iniltration of air.

3a)  Increase the immersion depth
3b)  Increase the immersion depth

4) 

Insuficient low

4a)  Pipes and accessories with diameter 

too small 

4b)  Presence of deposits or solid bodies 

in the impeller

4c) Rotor deteriorated 
4d) Worn rotor and pump case
4e) Gases dissolved in the water 
4f) 

 

Excessive viscosity of the liquid 
pumped

4g) Incorrect direction of rotation 

4a) Use pipes and accessories suitable for the speciic application 

4b) Clean the impeller and install a suction ilter

4c) Replace the impeller
4d) Replace the impeller and the pump casing 
4e) Perform the opening and closing manoeuvres through the feeder gate 
4f) The pump is unsuitable 
4g) Invert the electrical connections in the terminal board 

5) 
Noise and 
vibrations 
from the pump

5a) Worn bearings or bearing sleeve 
5b) Unbalanced power supply

5a) Replace the bearings or bearing sleeve
5b) Check that the mains voltage is right

Summary of Contents for VAL

Page 1: ...mps sump pumps Vertikale Tauchpumpen Pompes immerg es verticales VAL SC ISTRUZIONI ORIGINALI PER L USO Pagina 2 Italiano OPERATING INSTRUCTIONS Page 7 English BETRIEBSANLEITUNG Seite 12 Deutsch INSTRU...

Page 2: ...rimenti sono causa di danneggiamenti all apparecchio o compromettono la sicurezza del personale Informazioni ed avvertenze di carattere elettrico il cui mancato rispetto pu danneggiare l apparecchio o...

Page 3: ...8 9 10 16 15 14 13 12 11 Montorso VI Italy IT 00142630243 Made in Italy 3 CARATTERISTICHE TECNICHE 3 1 Dati tecnici Dimensioni di ingombro e pesi vedi catalogo Velocit nominale 2900 3450 rpm Protezio...

Page 4: ...vede che sul fondo del pozzetto possa formarsi della melma di deposito prevedere opportuno appoggio che mantenga l elettropompa sollevata Prevedere ancoraggi adatti alla lunghezza e peso della elettro...

Page 5: ...tenzione dell apparecchio contattare CALPEDA S p A 8 1 Manutenzione ordinaria OFF Nelle condizioni d impiego normali la pompa non richiede manutenzioni Prima di ogni intervento di manutenzione toglier...

Page 6: ...el dispositivo di protezione del motore d Fusibili bruciati o difettosi e Albero bloccato f Motore in avaria a Veriicare che la frequenza e la tensione di rete sia idonea b Collegare correttamente il...

Page 7: ...t be observed otherwise there is a risk that the machine could damage or compromise personnel safety The failure to observe electrical information and warnings could damage the machine or compromise p...

Page 8: ...220 380Y V3 50Hz cos X X X A XXXXXXXX S1 l cl X X kg X kW XHp S F 1 2 3 4 5 6 7 8 9 10 16 15 14 13 12 11 Montorso VI Italy IT 00142630243 Made in Italy 3 TECHNICAL FEATURES 3 1 Technical data Dimensio...

Page 9: ...ided to keep the pump raised Secure pump and delivery pipe to suitable rests 6 5 Electrical connection OFF Electrical connection must be carried out only by a qualiied electrician in accordance with l...

Page 10: ...the device could not accidentally operate The pump may have been immersed in hazardous substances or products emanating toxic gases or may be located in an environment which is toxic due to other reas...

Page 11: ...e overload protective device cuts in 1d Blown or defective fuses 1e Shaft blocked 1f Motor failed 1a Check that the mains frequency and voltage are suitable 1b Connect the power supply cable correctly...

Page 12: ...rechenden Bedeutungen im Folgenden aufgelistet Informationen und Hinweise welche zu beachten sind um Besch digungen an dem Ger t oder M ngel an der Sicherheit des Personals zu vermeiden Informationen...

Page 13: ...14 13 12 11 Montorso VI Italy IT 00142630243 Made in Italy 3 TECHNISCHE MERKMALE 3 1 Technische Daten Abmessungen und Gewicht siehe Katalog Nenndrehzahl 2900 3450 rpm Schutzklasse IP 54 IP 55 Sondera...

Page 14: ...alliert werden um oberhalb der Ablagerungen frei laufen zu k nnen Die Pumpe und die F rderleitung sind je nach L nge und Gewicht mit geeigneten Mitteln zu befestigen 6 5 Elektrischer Anschlu OFF Der e...

Page 15: ...Spannung gesetzt werden darf Die Pumpe k nnte in gesundheitsgef hrdenden bzw giftige Gase ausstr menden Fluiden eingesetzt worden sein Ebenso k nnen sich aus sonstigen Gr nden in dem Aufstellungsort d...

Page 16: ...cherungen defekt oder ausgel st e Welle blockiert f Fallsalle zuvorgenannten M glichkeiten berpr ft wurden liegt evtl ein defekt des Motors vor a berpr fen Sie ob die Netzfrequenz und spannung geeigne...

Page 17: ...compromettent la s curit du personnel Informations et avertissements de caract re lectrique qui s ils ne sont pas respect s peuvent causer des dommages l appareil et compromettre la s curit du person...

Page 18: ...RISTIQUES TECHNIQUES 3 1 Donn es techniques Dimensions d encombrement et poids voir catalogue technique Vitesse nominale 2900 3450 rpm Protection IP 54 IP 55 Construction sp ciale Tension d alimentat...

Page 19: ...ovoqu par eventuelles missions toxiques sur le lieu d installation Le diam tre int rieur du tube de refoulement ne peut tre inf rieur au diam tre de l oriice de la pompe Si des d p ts de vase sont sus...

Page 20: ...maintenance Les op rations de maintenance non d crites dans ce manuel doivent tre ex cut es uniquement par du personnel sp cialis envoy par CALPEDA S p A Pour toute autre renseignement technique conce...

Page 21: ...p ration Eviter le fonctionnement sec m me pour une courte dur e Suivre strictement les instructions d utilisation et si n cessaire contacter le revendeur ato PROBL MES CAUSES PROBABLES SOLUTIONS POSS...

Page 22: ...P A 1 Calpeda S p A 2 3 CE 8 3 1 6 5 6 5 1 1 i OFF ON 1 2 Calpeda S p A Via Roggia di Mezzo 39 36050 Montorso Vicentino Vicenza Italia www calpeda it 1 3 i 1 4 i 1 22 2 23 3 23 4 23 5 24 6 24 7 24 8...

Page 23: ...4 5 6 7 8 9 10 11 12 13 14 15 16 XXXXXXX Q min max X X m3 h XXXXXXX H max min X X m IP XX n XXXX min 220 380Y V3 50Hz cos X X X A XXXXXXXX S1 l cl X X kg X kW XHp S F 1 2 3 4 5 6 7 8 9 10 16 15 14 13...

Page 24: ...RU C 24 32 VAL_SC Rev24 5 5 1 25 6 6 1 6 2 3 2 6 3 i 6 4 0 6 0 6 p 6 5 OFF 07 RN F 12 3 TAB 1 I N 30 mA 3 D VALM SCM 50 220 240 7 7 1 7 2 OFF...

Page 25: ...RU VAL_SC Rev24 C 25 32 5 7 3 ON 6 5 8 i i Calpeda S p A Calpeda S p A 8 1 OFF rp n 8 2 OFF 73 00 64 24 70 18 78 00 64 00 52 00 14 24 14 00 28 04 28 00 28 20 64 00 8 3 IP55 OFF IP55 LOCTITE 510...

Page 26: ...12 13 16 13 20 14 00 14 24 14 29 28 00 28 04 28 08 28 20 50 00 52 00 52 04 54 00 54 04 54 08 56 00 64 00 64 08 64 20 64 24 70 00 70 18 70 20 73 00 76 00 76 04 76 54 78 00 81 00 82 00 82 04 82 08 88 00...

Page 27: ...rical diagram for single phase pumps VALM SCM with loat switch Schaltbilt f r einphasen Wechselstrompumpen VALM SCM mit Schwimmerschalter Sch ma lectrique pompes monophas es VALM SCM avec interrupteur...

Page 28: ...e Dessin pour d montage et montage Dibujo para desmontaje y montaje Ritning f r demontering och montering Onderdelentekening 88 00 82 00 82 04 81 00 92 00 73 00 70 00 70 18 56 00 54 04 90 00 76 00 94...

Page 29: ...lo smontaggio ed il rimontaggio Drawing for dismantling and assembly Zeichnung f r Demontage und Montage Dessin pour d montage et montage Dibujo para desmontaje y montaje Ritning f r demontering och...

Page 30: ...50 78 00 64 24 90 04 54 08 50 00 14 24 28 00 64 00 52 00 14 00 28 20 28 04 54 00 14 29 1 94 022 12 2 Disegno per lo smontaggio ed il rimontaggio Drawing for dismantling and assembly Zeichnung f r Dem...

Page 31: ...mm 2 Corrente nominale dell apparecchio Rated current of appliance Bemessungsstrom des Gerates Courant nominal de l appareil Corriente nominal del aparato Enhetens nominella str m Dimensiestroom van...

Page 32: ...e la Comisi n n 640 2009 DK OVERENSSTEMMELSESERKL RING Vi CALPEDA S p A erkl rer hermed at vore pumper VAL SC VALM SCM pumpe type og serie nummer vist p typeskiltet er fremstillet i overensstemmelse m...

Reviews: