MEASure:POWer[:REAL]?
This query returns the true power delivered to the unit under test by the AC source. Note
that the output relay must be closed to obtain current flow.
Query Syntax
MEASure:POWer[:REAL]?
Parameters None
Examples MEAS:POW?
Returned Parameters
<NR2>
Related Commands
MEAS:VOLT? MEAS:CURR?
MEASure:POWer:APParent?
This query returns the apparent power delivered to the unit under test by the AC source.
Note that the output relay must be closed to obtain current flow.
Query Syntax
MEASure:POWer:APParent?
Parameters None
Examples MEAS:POW:APP?
Returned Parameters
<NR2>
Related Commands
MEAS:POW?
MEASure:POWer:PFACtor?
This query returns the power factor. The power factor is the ratio between real power and
apparent power. This value is always between 0.00 and 1.00. If the current measured is too
low to determine the power factor, a 1.00 value is returned.
Query Syntax
MEASure:POWer:PFACtor?
Parameters None
Examples MEAS:POW:PFAC?
Returned Parameters
<NR2>
Related Commands
MEAS:POW? MEAS:POW:APP?
2001RP April
2007
89
Summary of Contents for 2001RP
Page 33: ...User and Programming Manual Rev N Figure 3 7 Test Setup 2001RP 24 April 2007 2001RP...
Page 47: ......
Page 60: ...User and Programming Manual Rev N Figure 6 3 Internal Adjustments 2001RP April 2007 51...
Page 65: ...User and Programming Manual Rev N Figure 7 1 Assembly Location 56 April 2007 2001RP...
Page 68: ...User and Programming Manual Rev N Figure 7 2 Replaceable Fuse Locations 2001RP April 2007 59...
Page 70: ...User and Programming Manual Rev N Figure 8 1 Rear Panel View 2001RP April 2007 61...
Page 90: ......