User and Programming Manual - Rev N
Parameter
Specification
External Sense
Will compensate for up to 7% of voltage drop up to 2kHz
Line Regulation
0.02 % of FS
Settling time
From start of voltage change from 5.0 V
RMS
or higher
voltage to within 2% of final value:
No load:
16 msec
Full load:
300 msec
(16 msec to within 15 % of final value)
Distortion
(THD
into linear load)
0.5 % typical, 1.0 % maximum below 100Hz
0.5 % + 0.5% per kHz above 100 Hz.
Distortion
(THD)
for AV option with
a full linear load
1% typical, 2% up to 1 kHz.
1% + 1% per kHz at and above 1 kHz.
DC Offset voltage
AC Coupled transformer output
Output noise
< 0.1 V
RMS
typical
( 20 kHz to 1 MHz at full load )
Temperature
coefficient:
± 0.02 % of full scale per degree C
Stability (24 hours)
± 0.015 % of full scale under constant load, line and
temperature
Total Power
2000 VA maximum at full scale voltage, either range
Current
Range
2001RP
2001RP-AV
2001RP-LZ
Volt Range
150
300
115
230
135
270
A
RMS
13.4
6.7
17.4
8.7
14.8
7.4
A
PEAK
44.5
22.2
58
29
49.4
24.7
Adjustable Limit
0.0 to Maximum available RMS current for selected
voltage range from 50% to 100% of programmed
voltage. For voltage < 50% of range, see V-I derating
chart on next page for available maximum RMS current.
Accuracy
Programmed value + 5, -0 % of maximum RMS current
2001RP April
2007
3
Summary of Contents for 2001RP
Page 33: ...User and Programming Manual Rev N Figure 3 7 Test Setup 2001RP 24 April 2007 2001RP...
Page 47: ......
Page 60: ...User and Programming Manual Rev N Figure 6 3 Internal Adjustments 2001RP April 2007 51...
Page 65: ...User and Programming Manual Rev N Figure 7 1 Assembly Location 56 April 2007 2001RP...
Page 68: ...User and Programming Manual Rev N Figure 7 2 Replaceable Fuse Locations 2001RP April 2007 59...
Page 70: ...User and Programming Manual Rev N Figure 8 1 Rear Panel View 2001RP April 2007 61...
Page 90: ......