User and Programming Manual - Rev N
10.5 Output Subsystem
This subsystem controls the main output function of the RP Series source.
Subsystem Syntax
OUTPut
[:RELay]
Opens or closes the output relay.
DROP
Drops the output voltage for a specified amount of time or
indefinitely.
STARt:
[STATe]
Enables or disables the start phase angle mode
PHASe
Sets the start phase angle value in degrees.
OUTPut[:RELay]
The output of the AC source can be isolated from the unit under test by opening the output
relay. The programmed output voltage is set to zero before opening the relay and is
returned to its programmed value when closing the relay. This avoids hot switching the
output relay contacts.
Command Syntax
OUTPut[:RELay] <bool>
Parameters
<Bool> 0 | 1
*RST Value
defined by the PONS
Examples OUTP
1
Query Syntax
OUTPut?
Returned Parameters
0 | 1
Related Commands
OUTP:DROP
OUTP:STAR
94 April
2007
2001RP
Summary of Contents for 2001RP
Page 33: ...User and Programming Manual Rev N Figure 3 7 Test Setup 2001RP 24 April 2007 2001RP...
Page 47: ......
Page 60: ...User and Programming Manual Rev N Figure 6 3 Internal Adjustments 2001RP April 2007 51...
Page 65: ...User and Programming Manual Rev N Figure 7 1 Assembly Location 56 April 2007 2001RP...
Page 68: ...User and Programming Manual Rev N Figure 7 2 Replaceable Fuse Locations 2001RP April 2007 59...
Page 70: ...User and Programming Manual Rev N Figure 8 1 Rear Panel View 2001RP April 2007 61...
Page 90: ......