User and Programming Manual - Rev N
10.6 Limit Subsystem
This subsystem controls the voltage frequency and current limit of the power source. These
limits are set at the factory and depend on the power source rating. It is not accessible by
the user. The query format is accessible however.
Subsystem Syntax
LIMit:
CURRent?
Queries
the
upper
current
limit
FREQuency:
LOW?
Queries
the
lower
frequency
limit
HIGH?
Queries
the
upper
frequency
limit
VOLTage?
Queries
the
upper
voltage
limit
LIMit:CURRent?
This command queries the maximum current limit the power source will operate at in the low
voltage range.
Command Syntax
LIMit:CURRent <NRf>
Parameters
maximum current limit at low voltage range
[command
protected]
Query Syntax
LIMit:CURRent?
Returned Parameters
<NR2>
LIMit:FREQuency:LOW?
This command queries the lower frequency limit of the power source. On the 2001RP-AV,
the frequency range may have been factory configured to a fixed single value. In this case,
the High and Low frequency limits will be set to the same value and both queries will return
the same number. Sending a frequency command with any value other than the set value
will result in a “-100, Command Error”.
Command Syntax
LIMit:FREQuency:LOW <NRf>
Parameters
Low freq limit [command protected]
Query Syntax
LIMit:FREQuency:LOW?
Returned Parameters
<NR2>
LIMit:FREQuency:HIGH?
This command queries the upper frequency limit of the power source. On the 2001RP-AV,
the frequency range may have been factory configured to a fixed single value. In this case,
the High and Low frequency limits will be set to the same value and both queries will return
the same number. Sending a frequency command with any value other than the set value
will result in a “-100, Command Error”.
Command Syntax
LIMit:FREQuency:HIGH <NRf>
Parameters
High freq limit [command protected]
Query Syntax
LIMit:FREQuency:HIGH?
Returned Parameters
<NR2>
2001RP April
2007
97
Summary of Contents for 2001RP
Page 33: ...User and Programming Manual Rev N Figure 3 7 Test Setup 2001RP 24 April 2007 2001RP...
Page 47: ......
Page 60: ...User and Programming Manual Rev N Figure 6 3 Internal Adjustments 2001RP April 2007 51...
Page 65: ...User and Programming Manual Rev N Figure 7 1 Assembly Location 56 April 2007 2001RP...
Page 68: ...User and Programming Manual Rev N Figure 7 2 Replaceable Fuse Locations 2001RP April 2007 59...
Page 70: ...User and Programming Manual Rev N Figure 8 1 Rear Panel View 2001RP April 2007 61...
Page 90: ......